- 37 -
TURNING REGENERATION BACK TO AUTO
Machine is not running:
Power the controller down. At next power up, the DPF
Regeneration settings will be back to default, and an
Automatic DPF Regeneration will take place at the
soonest appropriate moment.
Machine is running:
•
Make sure parameter '1142 ECU DPF REGENERA
-
TION ENABLE' is set to "ON"
•
Scroll down and Enter the 'MODE' parameter
•
Scroll down and Enter the 'AUTOMATIC' setting
•
Press the Back button 3 times to get back to the Main
view
FORCE DPF REGENERATION
Machine is running:
•
Press the Settings View Button
•
Enter the '1000 GENERAL SETTINGS' menu
•
Go to parameter '1130 STATIONARY REGENERA
-
TION'
•
Scroll to Enable and change to "ON"
•
Go to parameter '1140 ECU DPF REGENERATION'
•
Scroll to Enable and change to "ON"
SERVICE REGENERATION
Machine is running:
•
Press the Settings View Button
•
Enter the '7000 ENGINE' menu
•
Go to parameter '7140 SERVICE REGENERAION'
•
Scroll to Enable and change to "ON"
SETTINGS
For buttons to be used see “Control Panel”
Acknowledge an Alarm
If an alarm becomes active, for example a Low Fuel Level
Warning:
then this alarm can be acknowledged by pressing the
ENTER button. If the fuel level is still low, the view
will change to:
As soon as the fuel level is higher than the warning level,
the alarm icon will automatically disappear.
As long as there is an alarm icon in the middle of the
bottom part of the view, all active acknowledged /
unacknowledged alarms can be seen by pressing the
ALARM VIEW button
Pressing the ALARM VIEW button again, will bring you
back to the Main View.
Unit will not regenerate if soot level is not
high enough.
Unit will not regenerate if soot level is not
high enough.
Содержание XAS 185 KDU T4F HOP
Страница 2: ......
Страница 14: ... 14 Main parts ...
Страница 16: ... 16 Overview COMPRESSOR REGULATING SYSTEM LOAD CONDITION ...
Страница 20: ... 20 Electrical system Circuit Diagram 1310 3200 51 ...
Страница 21: ... 21 ...
Страница 49: ... 49 Adjustments and servicing procedures ADJUSTMENT OF THE CONTINUOUS REGULATING SYSTEM ...
Страница 57: ... 57 Altitude unit performance curve ...
Страница 59: ... 59 Maintenance log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 60: ... 60 ...
Страница 61: ......
Страница 62: ...www atlascopco com ...