- 88 -
HEATER FAILURE
Problem: Heater does not start when switched on.
Problem: Flame extinghuises.
Problem: Heater shuts off.
Problem: Control unit locked.
Possible faults
Corrective actions
No fuel.
Check fuel level.
Fuse blown.
Check fuse.
Bad electrical contact.
Check electrical wiring.
Blocked air duct or exhaust gas duct.
Check combustion air duct and exhaust gas duct.
Glow plug defective.
Replace glow plug.
Fan motor defective.
Replace fan motor.
Possible faults
Corrective actions
Overheating
Cool down and start again.
Possible faults
Corrective actions
Upper or lower voltage limit is reached.
Check power.
Possible faults
Corrective actions
Device switched off and on again too many
times.
Contact your agent.