- 11 -
regulations. Make sure that the unit has
sufficient air intake for operation. If
necessary, install extra air intake ducts.
3 When operating in a dust-laden
atmosphere, place the unit so that dust
is not carried towards it by the wind.
Operation in clean surroundings
considerably extends the intervals for
cleaning the air intake filters and the
cores of the coolers.
4 Close the compressor air outlet valve
before connecting or disconnecting a
hose. Ascertain that a hose is fully
depressurized before disconnecting it.
Before blowing compressed air through
a hose or air line, ensure that the open
end is held securely, so that it cannot
whip and cause injury.
5 The air line end connected to the outlet
valve must be safeguarded with a safety
cable, attached next to the valve.
6 No external force may be exerted on the
air outlet valves, e.g. by pulling on
hoses or by installing auxiliary
equipment directly to a valve, e.g. a
water separator, a lubricator, etc. Do
not step on the air outlet valves.
7 Never move a unit when external lines
or hoses are connected to the outlet
valves, to avoid damage to valves,
manifold and hoses.
8 Do not use compressed air from any
type of compressor, without taking
extra measures, for breathing purposes
as this may result in injury or death. For
breathing air quality, the compressed
air must be adequately purified
according to local legislation and
standards. Breathing air must always be
supplied at stable, suitable pressure.
9 Distribution pipework and air hoses
must be of correct diameter and suitable
for the working pressure. Never use
frayed, damaged or deteriorated hoses.
Replace hoses and flexibles before the
lifetime expires. Use only the correct
type and size of hose end fittings and
connections.
10 If the compressor is to be used for sand-
blasting or will be connected to a
common compressed-air system, fit an
appropriate non-return valve (check
valve) between compressor outlet and
the connected sand-blasting or
compressed-air system. Observe the
right mounting position/direction.
11 Before removing the oil filler plug,
ensure that the pressure is released by
opening an air outlet valve.
12 Never remove a filler cap of the cooling
water system of a hot engine. Wait until
the engine has sufficiently cooled
down.
13 Never refill fuel while the unit is
running, unless otherwise stated in the
Atlas Copco Instruction Book (AIB).
Keep fuel away from hot parts such as
air outlet pipes or the engine exhaust.
Do not smoke when fuelling. When
fuelling from an automatic pump, an
earthing cable should be connected to
the unit to discharge static electricity.
Never spill nor leave oil, fuel, coolant
or cleansing agent in or around the unit.
14 All doors shall be shut during operation
so as not to disturb the cooling air flow
inside the bodywork and/or render the
silencing less effective. A door should
be kept open for a short period only e.g.
for inspection or adjustment.
15 Periodically carry out maintenance
works according to the maintenance
schedule.
16 Stationary housing guards are provided
on all rotating or reciprocating parts not
otherwise protected and which may be
hazardous to personnel. Machinery
shall never be put into operation, when
such guards have been removed, before
the guards are securely reinstalled.
Содержание XAHS 186 Cud PNE
Страница 1: ...Instruction Manual for Portable Compressors English XAHS 186 Cud PNE Engine 6BT5 9 ...
Страница 2: ......
Страница 19: ... 19 Main parts ...
Страница 21: ... 21 REGULATING SYSTEM OVERVIEW ...
Страница 25: ... 25 ELECTRIC SYSTEM Circuit Diagram ...
Страница 26: ... 26 Wiring Diagram ...
Страница 27: ... 27 ...
Страница 49: ... 49 Adjustments and servicing procedures ADJUSTMENT OF THE CONTINUOUS REGULATING SYSTEM ...
Страница 66: ... 66 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 67: ... 67 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 68: ... 68 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 69: ......
Страница 70: ......