2. Switch on the voltage.
3. Close all manual condensate drain valves.
4. Press the start button (1). The compressor starts running and automatic operation LED
lights up.
5. The regulator will automatically stop and start the compressor modules in function of the air
pressure.
6. On compressors with integrated dryer, the nominal pressure dew point will be reached after
a few minutes.
The number of starts is limited to 30 starts per hour. See also section
Programmable
settings
.
5.3
During operation
Control panel
Procedure
1. If the automatic operation LED (3) is alight, the regulator is automatically controlling the
compressor modules (starting/stopping).
2. Check the readings on the display (1). In case of a warning or shutdown condition, see
section
Problem solving
or
Event history menu
.
3. Check that condensate is discharged automatically from the condensate drain outlet during
operation.
The dew point will deviate from nominal when the nominal conditions are exceeded. If
the dew point remains too high or unstable, consult section
Problem solving
.
Instruction book
82
2920 7140 52
Содержание SF 15+
Страница 1: ...INSTRUCTION BOOK OIL FREE SCROLL COMPRESSORS SF 15 SF 17 SF 22 SFD 11 SFD 15 SFD 22 ...
Страница 2: ......
Страница 16: ...2 2 Flow diagram Flow diagram of SF 15 SF 17 SF 22 Instruction book 14 2920 7140 52 ...
Страница 18: ...Flow diagram of SFD 11 SFD 15 SFD 22 Instruction book 16 2920 7140 52 ...
Страница 112: ......
Страница 113: ......