- 27 -
Maintenance
Daily inspection
When the light tower is in regular use, the following
items should be checked daily:
•
Check fluid levels and look for leaks.
•
Inspect all exposed wiring for damage, worn
insulation, and cuts.
•
Inspect winch cables for wear and damage.
•
If the light tower is vertical, verify the vertical-
lock pin is engaged and secure (see Figure 3.5,
page 22).
Repair or replace worn and damaged components
immediately. Never use any equipment that is
damaged or in need of repair.
Lamp replacement
To replace a light bulb (lamp), refer to Figure 4.1 and
follow the instructions below.
Figure 4.1 Lamp assembly
1. To remove a lamp:
a
Turn off power to all lamps and the control panel
receptacle.
b
Shut down the engine and allow the lamps to cool
for 15 minutes.
c
Remove the screws securing the flange rings and
remove the flange rings.
d
Remove the protective lamp cover with the gasket
attached.
e
Remove the hardware securing one side of the
lamp stabilizer. Once removed, swing the
stabilizer to the side and unscrew the lamp.
2. To install a lamp:
IMPORTANT!
Lamps will last longer if they are free of
contaminants. To protect a new lamp from the natural
oils on the fingertips, handle the lamp with cotton
gloves or a clean, soft cloth.
a
Insert the lamp into the socket and secure it with
the lamp stabilizer.
b
Ensure the gasket is fastened properly around the
lamp cover.
c
Secure the cover to the reflector with the flange
ring and screws.
DANGER
High voltage.
Contact with live electrical
circuits will cause severe
injury or death.
•
Turn off power before
servicing any component
on the light tower.
CAUTION
Risk of severe burn.
Before handling lights, allow
lights to cool for 15 minutes.
Bulb
Содержание QLT M10
Страница 1: ...QLT M10 Engine Kubota D1105 Instruction Manual For Portable Light Tower Generator English ...
Страница 2: ......
Страница 17: ... 17 Figure 2 2 Light fixture wiring ...
Страница 29: ... 29 Figure 4 4 Engine control circuit diagram 9829 3508 03 ...
Страница 30: ... 30 4 5 Circuit diagram 230V 50Hz with without universal socket 9829 3943 00 ...
Страница 31: ... 31 4 6 Circuit diagram 230V 50Hz Earth leakage breaker with without universal socket 9829 3944 00 ...
Страница 32: ... 32 4 7 Circuit diagram 240V 60Hz with without universal socket 9829 3537 00 ...
Страница 33: ... 33 4 8 Circuit diagram 120V 60Hz with GFCI socket 9829 3929 00 ...
Страница 34: ... 34 Figure 4 10 Circuit diagram Trailer wiring 1092 7120 00 ...
Страница 35: ... 35 Figure 4 11 Dimension drawing ...
Страница 36: ... 36 Figure 4 12 Dimension drawing ...
Страница 37: ... 37 Figure 4 13 Dimension drawing ...
Страница 38: ... 38 D900 axle with leaf springs use and maintenance manual Axle ...
Страница 40: ... 40 Wire Connection Cubicle 50HZ ...
Страница 41: ... 41 Wire Connection Cubicle 60HZ ...
Страница 42: ... 42 Wire Connection Cubicle 50Hz ELCB ...
Страница 44: ... 44 ...
Страница 45: ......
Страница 46: ......