5
Maintenance
5.1
Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
•
Stop the compressor.
•
Switch off the voltage and open the isolating switch.
•
Close the air outlet valve and open the manual condensate drain valves.
•
Depressurise the compressor.
For detailed instructions, see
Problem solving
.
The operator must apply all relevant
Safety precautions
.
Warranty-Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts is not covered
by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
Carry out maintenance at the interval which comes first. The local Atlas Copco Customer Centre may overrule
the maintenance schedule, especially the service intervals, depending on the environmental and working
conditions of the compressor.
The "longer interval" checks must also include the "shorter interval" checks.
Preventive maintenance schedule for GX 7 and GX 11
Period
Running hours
Operation
Daily
--
Check the oil level before starting. Drain the condensate after stopping.
For tank-mounted units, also drain the air vessel by means of the
manual drain valve (4), see
Stopping
.
3-Monthly
--
Check for possible leaks.
“
1000
Inspect the oil cooler, clean if necessary.
“
1000
For Full-Feature versions: inspect the condenser of the dryer; clean if
necessary.
“
1000
Inspect the air filter.
“
--
Inspect the condensate trap, clean the filter DA (for location of DA, see
Introduction
.
“
--
For compressors with PDX filter: check the service indicator, replace
the filter if necessary.
--
1000
Check the tension and the condition of the belts. Adjust, if necessary.
Instruction book
50
2920 7054 00
Содержание GX 11
Страница 1: ...GX 7 GX 11 Instruction book ...
Страница 2: ......
Страница 6: ...10 1 PRESSURE EQUIPMENT DIRECTIVES 71 Instruction book 4 2920 7054 00 ...
Страница 29: ...GX 7 and GX 11 Tank mounted 500 l optional Pack Instruction book 2920 7054 00 27 ...
Страница 30: ...GX 7 and GX 11 Tank mounted 270 l Full Feature Instruction book 28 2920 7054 00 ...
Страница 31: ...GX 7 and GX 11 Tank mounted 500 l optional Full Feature Instruction book 2920 7054 00 29 ...
Страница 32: ...GX 7 and GX 11 Floor mounted Pack Instruction book 30 2920 7054 00 ...
Страница 40: ...3 5 Electrical diagrams Electrical diagram GX 7 and GX 11 IEC Instruction book 38 2920 7054 00 ...
Страница 41: ...Electrical diagram GX 7 and GX 11 CSA UL Instruction book 2920 7054 00 39 ...
Страница 74: ......