To modify the terminal bridge configuration to the motor, configure the terminal bridges for the desired voltage
(208 V, 230 V or 460V) according to the diagram below. The terminal bridges (1) can be easily removed
using a pair of pliers. Additional terminal bridges are provided with the compressor. The connections for 230
V are the factory standard.
Locate the yellow voltage labels provided with the compressor. Replace the existing label with the appropriate
voltage label (200-208 V, 230V or 460V).
Voltage labels for GX 7 and GX 11
2. Dryer transformer cubicle modifications
Remove the rear panel and the transformer box rear cover. Use fuses F11 only for a supply voltage of 460 V.
F11 is not to be used for a supply voltage of 208 - 230 V.
Instruction book
36
2920 7054 00