![Atlas Copco GA 55+ Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/atlas-copco/ga-55/ga-55_instruction-book_3001662113.webp)
113
Instruction book
9096 3313 00
Control panel Elektronikon Graphic
Step Action
-
Switch on the voltage. Check that voltage on LED (6) lights up.
-
Open the air outlet valve.
-
Press start button (1) on the control panel. The compressor starts running and the
automatic operation LED (8) lights up. Ten seconds after starting, the drive motor
switches over from star to delta and the compressor starts running loaded.
-
On water-cooled compressors, regulate the cooling water flow during loaded running
to obtain the most suitable temperature at the outlet of the compressor element, i.e.
between 2
o
C and 7
o
C above the relevant temperature in the figure below. For
optimum operation, the cooling water outlet temperature must never exceed the valve
specified in section Compressor data. Consult Atlas Copco if condensate should form
during frequent unloading periods.
Содержание GA 55+
Страница 1: ...GA 55 GA 75 GA 90 Instruction book Atlas Copco Oil injected rotary screw compressors ...
Страница 2: ......
Страница 4: ......
Страница 9: ......
Страница 96: ...96 Instruction book 9096331300 6 Installation 6 1 Dimension drawings Centre of gravity ...
Страница 98: ...98 Instruction book 9096331300 6 2 Installation proposal Compressor room example ...
Страница 109: ...109 Instruction book 9096331300 ...
Страница 123: ...123 Instruction book 9096331300 Procedure Oil system components Oil drain plugs ...
Страница 145: ...145 Instruction book 9096331300 Notes ...
Страница 146: ...146 Instruction book 9096331300 Notes ...
Страница 147: ...147 Instruction book 9096331300 Notes ...
Страница 148: ......
Страница 149: ......