• Programming the command to change over at 18 o’clock to ‘Press Band 2’ is carried out in a
similar way as described above.
• Press the key ‘Menu’ (F1) and scroll to ‘Saturday’. Programming the command to stop at 18
o’clock is carried out in a similar way as described above.
Activating/deactivating the timer
• The timer can only be activated if at least one start/stop command is programmed.
• Starting from the Main screen, press the key ‘Menu’ (F1).
• Use arrow down key (1) until the option ‘Modify Params’ is followed by a horizontal arrow.
• Press the tabulator key (2) to activate the menu.
• Use the arrow down key until the option ‘Clock Function’ is followed by a horizontal arrow,
press the tabulator key (2), the following screen appears:
‘Clock Function’
‘Not activated’
.
‘Menu’
‘Mod.’
‘Del’
F1
F2
F3
• Press the key ‘Mod.’, ‘Not Activated’ starts flashing.
• Press the arrow down key (1) ‘Not Activated’ changes to ‘Activated’.
• Press the key ‘Prog’.
It is necessary to program the start/stop commands in successive order time-wise. Program
the commands from ‘Monday’ till ‘Sunday’, e.g.:
• 07.30 ‘Start’ ‘Comp’
• 07.30 ‘Press Band 1’
• 08.30 ‘Press Band 2’
• 18.00 ‘Stop’ ‘Comp’
Make sure that the timer function is activated (‘Activated’). If not, the programmed start/stop
commands will not be executed.
The timer can be deactivated again. In this case, the programmed start/stop commands will
not be executed (but remain in the memory of the regulator).
Modifying a command
Suppose the command to stop the compressor on Saturday is to be modified, i.e. stopping at 17
o'clock instead of 18 o'clock.
• Starting from the Main screen, press the key ‘Menu’ (F1); press the arrow down key (1) until
the option ‘Modify Params’ is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• Use the arrow down key (1) to scroll until the option ‘Clock Function’ is followed by a
horizontal arrow. Press the tabulator key, the following screen appears:
Instruction book
API161475
35
Содержание GA 11 VSD
Страница 1: ...INSTRUCTION BOOK API161475 GA 11 VSD ...
Страница 2: ......
Страница 24: ...Menu flow for GA 5 up to GA 11 VSD simplified Instruction book 22 API161475 ...
Страница 55: ...Position of oil level sight glass Instruction book API161475 53 ...
Страница 83: ......