Unit is shut down
The alarm LED (4) will flash indicating either that the outlet temperature is too high or that the motor
overload relay has tripped. Remedy the problem.
Move the cursor to the action button
Menu
and push the Enter key (10). Using the Scroll keys (12), move
the cursor to the protections icon. Push the Enter key (10). Move the cursor to the blinking icon and press
the Enter key (10). Move the cursor to the Reset button and press the enter key again.
Multiple shut-down
If there are multiple sequential failures with short time intervals on a specific shut-down functionality,
consult your Atlas Copco Customer Centre.
Excessive oil consumption
Have the compressor inspected by your Atlas Copco Customer Centre.
Condition
Fault
Remedy
Condensate is not discharged from
condensate traps during loading.
Discharge pipe of condensate
trap clogged.
Check and correct as necessary.
WSD (electronic water drain)
malfunctioning.
Consult Atlas Copco.
Condition
Fault
Remedy
Compressor air delivery or pressure
below normal.
Air consumption exceeds air
delivery of compressor.
Check equipment connected.
Choked air filters.
Replace filters.
Air leakage.
Check and correct.
Condition
Fault
Remedy
Compressor element outlet
temperature or delivery air
temperature above normal.
Oil level too low.
Check and correct.
Oil coolers clogged.
Refer to the
Coolers
section.
Air cooler clogged.
Refer to the
Coolers
section.
On air-cooled compressors,
insufficient cooling air or cooling
air temperature too high.
Check and correct as necessary.
Instruction book
APF221384
75
Содержание APF221384
Страница 1: ...Instruction book APF221384 G 160 VSD ...
Страница 2: ......
Страница 51: ...4 4 Main fuses and supply cables section maximum length Electrical connections Instruction book APF221384 49 ...
Страница 80: ...Units G 160 VSD Sound pressure level dB A 80 Instruction book 78 APF221384 ...
Страница 83: ...11 Documentation Instruction book APF221384 81 ...
Страница 84: ......
Страница 85: ......