Topic
Description
Emergency stops
Displays the number of compressor stops by use of the emergency stop
REGULATION
Topic
Description
Unloading pressure 1
The pressure setpoint that is higher than setpoint 1, where the loaded
compressor switches to unload
Loading pressure 1
The pressure setpoint that is lower than setpoint 1, where the unloaded
compressor switches to load
Unloading pressure 2
The pressure setpoint that is higher than setpoint 2, where the loaded
compressor switches to unload
Loading pressure 2
The pressure setpoint that is lower than setpoint 2, where the unloaded
compressor switches to load
Pressure band used
Selection of 1st or 2nd pressure band. A pressure band is a combination of a
loading pressure, a setpoint and an unloading pressure
Digital pressure band
selection
Allows a remote signal to control the pressure band selection.
Reduced unload
pressure
The unload pressure is reduced
Reduced load pressure
The load pressure is reduced
Reduced setpoint
The setpoint is reduced
Setpoint 1
Value of setpoint 1
Indirect stop level 1
Value of indirect stop level 1
Direct stop level 1
Value of direct stop level 1
Setpoint 2
Value of setpoint 2
Indirect stop level 2
Value of indirect stop level 2
Direct stop level 2
Value of direct stop level 2
Setpoint used
Which setpoint is used
Regulation mode
In which regulation mode is the compressor
Digital pressure band
selection
Which pressure band is selected
Maximum speed factor
Value of the maximum speed factor
INPUTS
Topic
Description
General
Displays a number of general readouts and bipolar states
Element(s)
Displays a list of readouts related to the compressor stages
Fan
Displays the status of the fan
Filter
Displays the status of the filter
Converter(s)
Displays the status of the converter(s)
Main Motor
Displays a number of readouts and bipolar states concerning the main motor
Network
Displays a number of bipolar states of remote signals
Oil Circuit
Displays a number of readouts and bipolar states concerning the oil circuit
Instruction book
32
APF221384
Содержание APF221384
Страница 1: ...Instruction book APF221384 G 160 VSD ...
Страница 2: ......
Страница 51: ...4 4 Main fuses and supply cables section maximum length Electrical connections Instruction book APF221384 49 ...
Страница 80: ...Units G 160 VSD Sound pressure level dB A 80 Instruction book 78 APF221384 ...
Страница 83: ...11 Documentation Instruction book APF221384 81 ...
Страница 84: ......
Страница 85: ......