Instruction book
2920 1521 00
64
8.15 Programmable settings
8.15.1 Regulation settings
Minimum
setting
Nominal
setting
Maximum
setting
Number of motor starts
starts/day
240
720
720
Minimum stop time
1)
sec
5
5
30
Stop between 2 compressor
modules
sec 2 2 5
Start between 2 compressor
modules
sec 2 2 10
Power recovery time
3)
sec
10
10
3600
Delay at restarting after
power recovery
3)
sec 0 0 1200
Minimum pressure
2)
8 bar Pack
bar(e)
4
7
7.9
8 bar Full-Feature
bar(e)
4
6.8
7.7
10 bar Pack
bar(e)
4
9
9.9
10 bar Full-Feature
bar(e)
4
8.8
9.7
100 psi Pack
bar(e)
4
7
7.9
100 psi Full-Feature
bar(e)
4
6.8
7.7
125 psi Pack
bar(e)
4
8.1
9
125 psi Full-Feature
bar(e)
4
7.75
8.8
145 psi Pack
bar(e)
4
9
9.9
145 psi Full-Feature
bar(e)
4
8.8
9.7
Maximum pressure
2)
8 bar Pack
bar(e)
4.1
8
8
8 bar Full-Feature
bar(e)
4.1
7.8
7.8
10 bar Pack
bar(e)
4.1
10
10
10 bar Full-Feature
bar(e)
4.1
9.8
9.8
100 psi Pack
bar(e)
4.1
8
8
100 psi Full-Feature
bar(e)
4.1
7.8
7.8
125 psi Pack
bar(e)
4.1
9.1
9.1
125 psi Full-Feature
bar(e)
4.1
8.9
8.9
145 psi Pack
bar(e)
4.1
10
10
145 psi Full-Feature
bar(e)
4.1
9.8
9.8
For Full-Feature also
4)
Dewpoint warning
temperature
°C 3 15
40
Delay at signal
5)
sec 0
3
10
Delay at starting
6)
sec
0
255 255