Atlantic TidalWave FP100 Series Скачать руководство пользователя страница 4

1-877-80-PONDS 

www.atlanticwatergardens.com

Problem

Possible Cause

Possible Solution

Pump does  
not run

Power is off

Turn power on

Power failure

Check power supply or  
contact local power company

Power cord is not  
connected

Connect power cord

Impeller is stuck

Remove debirs/clean impeller

Pump stops after 
starting

Pump is  
overheating

Submerge pump/Raise water level/ 
Allow pump to cool/Clean impeller

Power/Current  
overload

Check length/size of power cable. 
Check or replace GFI

Intake is blocked/ 
Impeller needs cleaned      

Remove debris from the pump  
intake. Refer to page 5 for  
cleaning instructions.

Diminished  
flow rate or  
no water flow

Impeller needs cleaned

Refer to page 5 for cleaning instructions

Obstruction in pump  
or piping

Clear obstruction

Low water level

Stop operation/Raise water level

Air-lock in the  
impeller chamber

Place pump in water. Turn the pump 
ON/OFF intermittently 2 or 3 times.

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can 
result in a serious accident.

Before ordering repairs, carefully read through this instruction booklet. If the problem  
persists, contact your dealer.

rev. 3/12