Prior to Operation and Installation

•  When the pump is delivered, first perform the following checks:

 

•  Check for any damage to pump and power cable that may have occurred during  

 

 

the shipment.

 

•  Check the model number to make sure it is the product that was ordered and verify  

 

 

the voltage and frequency are correct.

Caution

•  DO NOT operate this product under any condition other than those for which it is  
 

specified. Failure to observe this precaution can lead to electrical shock, electrical  

 

leakage, fire, water leakage or other problems.

•   The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage  
 

within 110-120 volt 60 Hz.

•  Never place your hand or any object in or near the inlet opening while this equipment is  
 

operating. If pump inlet is clogged, always turn off the power supply and wait until the  

 

motor is completely stopped before attempting to remove any clogged material.

•  Please make sure that the power plug and the AC outlet receptacle are protected and away  
 

from water or pump discharge hose to prevent accidental electric shock or short circuit.

•  Always operate the pump completely submerged in water.

•  Avoid dry operation, which will not only lower performance but can cause the pump to  
 

overheat/malfunction, leading to electrical leakage, shock or premature failure.

•  Always turn off power or unplug the pump prior to performing any maintenance or  
 

placing your hands into the water.

• 

CAUTION:

   

 

THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.

Introduction

Thank you for selecting the TidalWave FP100, FP200, FP300, FP400 or FP500 series 
pump. Before using this pump please take a moment to review this manual.

To avoid  an accident do not use the pump in any way other than as described in this 
manual. Please note the manufacturer cannot be responsible for accidents arising because 
the product was not used as prescribed. After reading this manual keep it as a reference 
in case questions arise during use.

2

3

Flow Chart:

•  

CAUTION:

  

 

THIS PUMP HAS BEEN EVALUATED FOR USE IN  WATER ONLY.

•  

WARNING:

 

 

RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR  

 

AND GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK,  

 

BE CERTAIN THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING  

 

TYPE RECEPTACLE.

Electrical Safety

•  Electrical wiring should be installed by a qualified electrician in accordance with all  
 

applicable safety regulations. Incorrect wiring can lead to a pump malfunction, electrical  

 

shock or fire.

•  Pumps should operate on a designated, 110/120 volt circuit.

•  Pump must be protected by a ground fault circuit interrupter (GFCI).

•  Pump must be plugged into a standard, properly grounded, three pronged outlet.

Safety Instructions

ATTENTION

Make sure the pump works at a proper water level. Do 
not operate the pump without water. If so, the pump 
should be turned off immediately and check.

•  Do not lift, lower or handle the pump by pulling on the electrical cord. Make sure the  
 

electrical cable does not become excessively bent or twisted and does not rub against a  

 

structure in a way that might damage it. (Fig. 1)

•  Always disconnect the power supply before doing any maintenance or placing your hands  
 

into the water to which this pump is immersed. (Fig. 2) 

•  The submersible pump should not be used if the electrical supply cable is damaged in  
 

any way. If a cable with damaged insulation is submerged in water, there is danger of  

 

water seeping into the pump motor and causing a short. The electrical cable cannot be  

 

replaced. If the cord is damaged, the pump should be discarded. Altering the electrical  

 

cable in any way will void the warranty. (Fig. 3)

Operation

•  Fountain Series pumps are for use in water only. Water temperature should never  
 

exceed 95˚ F (35˚ C).

Max 

2.5’ 

5’ 

7.5’

Model #

Watts

9.5 

16 
24 
33

FP100 
FP200 
FP300 
FP400 
FP500

120 
175 

100 

325 

230 

90 

370 

290 

180 

525 

430 

300 

75

Fig. 1

Fig. 2

Fig. 3