24
Switch off the electricity supply to the appliance before carrying out any
maintenance on it. You must remove dust from the appliance around
twice a year to maintain its performances.
Never use abrasives or solvents.
SERVICING
FITTING AND REMOVING THE HOOKS
3
-
Carry out the following checks to make sure that the programming
orders are being correctly transmitted:
COMFORT
E
CO
F
ROST
PROTECTION
S
TOPPING
HEATING
S
HEDDING
COMFORT
-1° C
COMFORT
-2° C
SIGNAL
TO
BE
TRANSMITTED
MEASUREMENT
BETWEEN
THE
PILOT
WIRE
AND
THE
NEUTRAL
0
VOLT
230
VOLT
-115
VOLT
NEGATIVE
+ 115
VOLT
POSITIVE
230
VOLT
FOR
3
S
230
VOLT
FOR
7
S
-
For programming by pilot wire or bearer current, the frost protection
or shedding orders take priority.
-
It takes around 12 seconds to switch from Comfort mode to Eco
mode.
-
It takes around 5 minutes to switch from Comfort -1/-2 mode to
Comfort mode.
-
You can remotely control the ECO, COMFORT, OFF and Frost
Protection modes and program your product by equipping your
device with a connected 6-command pilot wire interface and a bridge.
Содержание SFLC DIG2
Страница 1: ...1 OK 19 0 ...
Страница 120: ...120 U0648871 D JANV 20 ...