Pilot Wire Connection Test
You may connect the pilot wire if your house has a scheduler or energy manager.
In this case, to check that the scheduling orders are correctly transmitted, conduct the following checks:
Orders
Received
No
power
230V for 3s
230V for 7s
230V
-115V ne115V positive
Signal to
transmit
Mode Obtained
COMFORT
COMFORT -1°C COMFORT -2°C
ECO
FREEZE
PROTECTION
LOAD
SHEDDING
HEATING STOP
For scheduling through the pilot wire or carrier power, freeze protection and load shedding orders have priority.
The delay for switching over from comfort mode to eco mode is about 12 seconds.
2.4 - Lock the Device on its Wall Bracket
- Place the device on bracket
S
as shown. - Move the device
towards the bracket then lift (arrows 1 and 2).
- Insert the bracket flanges in the holes on the device and lower
(arrow 3).
- Lock by turning the two latches (V) half a turn, your device is
locked.
3 - Controls
Screen
and
keys
and keys
OK/Validate - Stop heating
Menu
Ventilation
Equilibrium
Consumption Indicator
3.1 - Familiarization
First check that the device is on. If it is off, press and hold the
key to start.
Activate the screen by pushing any key.
You may choose the heating mode by pushing the and keys and validating with
.
Flashing data has not yet been validated.
You may also set comfort and eco mode temperatures using the
and
keys then validating with
.
For more information regarding the numerous possibilities offered by your device, please consult the following
sections in this Guide.
If you do not use the controls the screen goes into standby mode.
3.2 - Control Screen Description
Ventilation function
Information line
Controls locked
Schedule display
Heating indicator
Display T°C
Modes