OPERATING PRINCIPLE 

 

 

Increasing  and  decreasing 

temperature (7°C to  30°C in Manual 
Mode only) without further mandatory 
confirmation

 

 

Navigation through the menu; 

Confirmation; 

Switching off; 

Blocking, unlocking 

 

OPERATING MODES 

 

The appliance has 2 operating modes: 

 

Manual 

The appliance constantly maintains the temperature set in the settings. 

 

Prog 

The  appliance  runs  an  internal  program  configured  for  each  day  of  the 
week. Once the appliance is switched on, the user can set the following 
adjustment ranges: 
Monday, Tuesday, Thursday and  Friday, Comfort from 6.00 to 8.00 and 
from 18.00 to 22.00. Wednesday Comfort from 6.00 to 8.00, from 12.00 to 
14.00 and from 18.00 to 22.00. Saturday and Sunday, Comfort from 6.00 
to 22.00. The user can change the specified ranges and set up to 3-time 
ranges  in  Comfort  mode  for  each  day  of  the  week.  During  execution  of 
these Comfort ranges, the set temperature can be adjusted with 

 or 

. Outside the Comfort ranges, the set temperature is the Eco temperature, 
which  can  be  set  in  Temp.  ECO  section  (see  “Menu  in  PROG  mode” 
section). 
 

SWITCH 

 

On the back of the appliance’s control unit there is On/Off button. 
Use  this  switch  only  when  you  stop  the  heating  for  a  long  time  (out  of 
heating season). To energize the appliance, set the On/Off button into 

 

position. If the appliance is disconnected from the supply voltage, you will 
have to re-set the date and time when switching on your appliance. 

 

FIRST USE 

 

Select your language, and then  date and time. When you switch  on  the 
appliance for the first time: 

Содержание F129 Design CMG-BD 1

Страница 1: ...F129 DESIGN Operating manual CMG BD1 U0628726 ELECTRICAL CONVECTOR This product is only suitable for well insulated spaces or occasional use ...

Страница 2: ...2 ...

Страница 3: ...y are monitored correctly or instructions for using the appliance safely given to them and if the risks were apprehended Children should not play with the appliance Cleaning and maintenance by the user should not be performed by children without supervision This appliance may only be plugged in or connected by an authorized person according to valid regulations and rules If the power cable is dama...

Страница 4: ... Do not use this heating appliance in small rooms when people with limited mobility are present who cannot leave the room unaided unless constant supervision is provided F129 DESIGN WITH ELECTRONIC THERMOSTAT Atlantic brand founded in 1968 is known for its specialization in heating systems thermal comfort and energy saving technologies New F129 Design model purchased by you comes with 40 years of ...

Страница 5: ...otected from water splashes to IP 24 They may therefore be installed in zone 2 of shower rooms It is forbidden to install the device in zone 1 It must be impossible for anyone using the shower or bath to reach the appliance s controls however Respect minimum distances to obstacles when positioning the appliance The appliance s support bracket allows to maintain a free space behind the appliance so...

Страница 6: ...centrally controlled mechanical fan unit etc Underneath a fixed mains socket or near curtains or any other flammable materials The air outlet grid and control unit must be visible at the top of the appliance It is forbidden to mount a vertical device horizontally and vice versa Mobile version Your model can be installed both in portable mobile and fixed version CAUTION The appliances which are not...

Страница 7: ...the tongue raised push the latching bar downwards to release the latches at the top Pivot the latching bar around the lower latches Remove the latching bar Fix the latching bar Place the latching bar on the floor against the wall Locate the drilling points A These show you where the lower fastenings are Lift the latching lug aligning it with the drilling point A to locate the drilling points B The...

Страница 8: ...atching bar behind the appliance towards the wall Lift the appliance while holding the tongue with the screwdriver Swing it forward then lift it off the supports S1 Electric connection The power supply to the appliance is 220 240V 50Hz 60Hz In damp atmospheres such as bathrooms and kitchens the junction box must be located at least 25 cm from the floor The appliance s power supply must be connecte...

Страница 9: ...8 00 to 22 00 Saturday and Sunday Comfort from 6 00 to 22 00 The user can change the specified ranges and set up to 3 time ranges in Comfort mode for each day of the week During execution of these Comfort ranges the set temperature can be adjusted with or Outside the Comfort ranges the set temperature is the Eco temperature which can be set in Temp ECO section see Menu in PROG mode section SWITCH ...

Страница 10: ...ture which is unchangeable using In PROG mode PROG 20 0º 19 30 If the display shows PROG you can set the programming range in Comfort mode Increase the temperature using max 30 C Decrease the temperature using min 10 C PROG ECO 16 0º 19 30 If the display shows PROG ECO you can set the programming range in ECO mode To change the temperature in ECO mode range go to Temp ECO menu see Menu in PROG mod...

Страница 11: ...the week see The Use of Internal Programs section Clock To set the date and time Off To switch the appliance off Back To go back to start screen THE USE OF INTERNAL PROGRAMS Anticipation of heating Your device is equipped with a function that allows your device to anticipate the heating when you use programming When you set the programming of your device it will anticipate the heating according to...

Страница 12: ... start time using or Confirm Select the end time using or Confirm How to copy the Program You can copy the program from a certain day to another day s Select Confirm Scroll through the days using or Select the day to which the program is copied using To confirm the copying select Copy Confirm Monday Example Copying the program from Monday to Tuesday Thursday Friday Tue Fri Wed Sat Thu Sun Copy ...

Страница 13: ...nguage To select the language Restrictions Max temp To record the maximum setpoint temperature that cannot be exceeded in the interval between 22 C and 30 C Access control To limit the access to controls Full access access to temperature only or no access can be selected In the latter case access to unit controls is prohibited PIN code To enable and disable entering personal access code to Expert ...

Страница 14: ...ptive activation control Yes Activation duration limit No Black globe sensor No MAINTENANCE ATTENTION All operations are performed only with the device completely de energized In order to maintain the performance of the appliance you should use a vacuum cleaner or brush twice a year to remove the dust from the upper and lower grids Every five years a maintenance engineer should check the inside of...

Страница 15: ... very hot It is normal that the convector is hot when operating it being understood that the surface temperature is limited according to the current standard However if you feel that your appliance is still too hot verify that the power is correct for the surface area of your room we recommend on average 100 W m2 and the appliance is not in a draught that would affect its setting CONTACTS ATL Inte...

Страница 16: ...pproved by Atlantic Australasia Alantic Australasia Pty Ltd reserves the right to reject any warranty claims used in conditions other than domestic purpose or connected to non approved power boards extension leads double adaptors and power boards All products returned to retail stores for replacement must be pre approved by Atlantic Australasia To apply for warranty service please contact your dis...

Страница 17: ...Standards quality labels B Commercial name C Commercial reference D Manufacturing reference E Serial number F Manufacturer number Type of Device Serial Number Name and address of the customer INSTALLER STAMP ...