Wall outlet cable
Sealing tape
or other
Pressure reducer
Mandatory if the water pressure
in your house is greater than 5 bar
(0.5 MPa). It must be installed at
the meter outlet (see page 26)
Water retention tank
Essential in the case of an instal-
lation on the floor and above a
living space
Installation manual : Place of installation
2. Where to install my water heater?
2.1 Precautions
• Choose a place of installation whose temperature is always between 4°C and 35°C.
• The water heater must be positioned as close as possible to the major draw-off points (bathroom,
kitchen, etc.)
• If it is positioned outside the living area (cellar, garage), the pipes and the safety units (safety unit,
pressure limiter) must be insulated.
• Make provision in the room for ventilation to prevent condensation and corrosion of the water
heater paint.
• Make provision for a space of 40 cm for the periodic maintenance of the heater element.
• In the case of installation above living rooms (suspended ceilings,
attics, etc.), it is ESSENTIAL to make provision for a water collection
tank connected to the drain under the water heater (shower type
tank for example).
• The installation of the water heater requires no fixing. Make sure
to install it on a flat surface
2.2 Specific installation in the bathroom
• Installation in Area 3
and outside these areas (NF C 15-100).
If the dimensions of the bathroom do not allow the water heater to be positioned in area 3 or not in
this area :
0,60 m
0,60 m
0,60 m
Area
1
Area
2
Area
3
0,60 m
0,60 m
0,60 m
Area
1
Area
2
Area
3
0,60 m
0,60 m
0,60 m
Area
1
Area
2
Area
3
Possible in Area 2
Possible in Area 1 if :
- the water heater is horizontal and positioned
as high as possible
- the pipes are made from conductive material
- the water heater is protected by a circuit
breaker 8 residual differential current (30m A)
connected
In order to replace the magnesium anode, provide a ceiling height of 2.30 m minimum