Atlantic 74227 Скачать руководство пользователя страница 8

8

The Eco-Rise System
Plumbing the PV7500 (Eco-Rise System)

The PV7500 comes pre-drilled for use with the Eco-Rise Diverter for multiple 
features or 11/2” pipe for a single larger feature. 
If multiple pumps are needed, the other side 
will need to be drilled. Bore a 23/8” diameter 
hole using the molded drill point as a guide.

Eco-Rise Diverters mount in the molded 
pockets on the neck of the PV7500 Pump 
Vault. Either one or two may be used, but 
each should be plumbed to its own pump. 
Insert the Diverter into the hole in the pocket 
and secure with the supplied hardware. 

Next install the pump and Triton Check Valve, 
following the instructions included with the 
Check Valve. Cut the Check Valve discharge 
pipe at Perfect Cut Line B for TT1500, TT2000, 
TT3000 and TT4000. Determine whether 
you need the 2” outlet fitting for the Eco-Rise 
Diverter or the 11/2” outlet fitting for 11/2” pipe. 
Set the finished assembly in the Vault and 
attach to either Diverter or pipe. See page 9 
for Perfect Cut Chart.

The AF1000 Automatic Fill Valve is optional 
but strongly recommended to keep the water 
level in the reservoir safely above the pump, 
avoiding pump burnout. Mounting locations 
are provided on either side of the PV7500. 
Follow the Auto Fill instructions to install. 

Excavating and Setting the PV7500 (Eco-Rise System)

The size of the reservoir depends on the size, height and number of the decorative fountain 
elements. For a general rule of thumb, the basin should extend out at least twice the  
height of the decorative elements in all directions. A three-foot-tall by one-foot-wide 
column would require a seven-foot splash zone. The Eco-Blox reservoir only needs to be 
large enough to support the decorative items. The liner can then be oversized to create 
a ‘splash skirt’ around the basin to recapture as much water as possible with minimum 
additional excavation.

Once you have determined the size and shape of the reservoir, lay out the Eco-Blox and 
Pump Vault. The Vault should be placed at the perimeter of the excavation where the lid 
can be accessed easily, typically closest to the electric service. Make sure the pump cord 
will reach. 

After determining the size and shape of the reservoir, excavate at least a foot wider and 
longer than required to leave room for backfilling. Excavate the entire area of the basin to a 
depth of 13”. This will accommodate one layer of Eco-Blox Small plus the gravel to hide the 
reservoir. Dig the area where the PV7500 Pump Vault will sit 71/2” deeper to accommodate 
it. The additional depth will help ensure the pump remains completely submersed. Level 
and tamp the bottom, then cover the bottom and sides with underlayment to protect the 
liner, carefully working it into the corners and the deeper Vault area. Set the liner over the 

Содержание 74227

Страница 1: ...PV1700 74235 PV7500 89583 PV15000 89584 PVEXT 89858 SP1600 74271 SP1900 74227 SP2600 74228 SP3800 74229 Product Manual Manuel du Produit Manual del Producto 1 330 274 8317 www ATLANTIC_OASE com PF...

Страница 2: ...By calculat ing the transitional water volume then designing the reservoir to hold at least three times as much the water level in the reservoir will never drop by more than one third when the system...

Страница 3: ...drops as the pump turns on and the stream fills the smaller the reservoir can be Proper streambed construction can reduce the amount of water needed Since transitional volume is determined by how hig...

Страница 4: ...TE For best results install the pump and optional Autofill before installing the Vault in the reservoir following the instructions in the next sections Install the plumbed Vault in the excavation ensu...

Страница 5: ...l Plumbing the PV1700 Pump Vault The PV1700 is Atlantic s most compact easy to install pump vault The PV1700 features an incredibly strong enclosure pump discharge step fittings molded into each side...

Страница 6: ...tubing size and port locations to any application with multiple drill points and flat panels The top of the Vault accommodates Auto Fill and overflows Flat panels at the bottom accept 3 bulkheads for...

Страница 7: ...port for a lip rock The Fastfalls will support the weight of gravel and rocks stacked directly on top of the unit Consider covering the whole unit with a single sizeable overhanging capstone or stack...

Страница 8: ...the PV7500 Eco Rise System The size of the reservoir depends on the size height and number of the decorative fountain elements For a general rule of thumb the basin should extend out at least twice t...

Страница 9: ...the discharge pipe will be used Discharge Pipe Perfect Cut Reference Chart Shaded areas denote pumps that exceed maximum flow rates or dimension for use with the corresponding Pump Vault Use of this...

Страница 10: ...isused or abused product voids this warranty Pump Vault Accessories AF1000 Auto Fill Kit and TR215CV Triton Check Valve included in this manual carry a one year warranty This warranty excludes labor c...

Страница 11: ...ins trois fois plus le niveau d eau dans le r servoir ne baissera jamais de plus d un tiers lorsque le syst me est d marr gardant la pompe immerg e en toute s curit tout moment En supposant qu il faud...

Страница 12: ...r duire la quantit d eau n cessaire tant donn que le volume de transition est d termin par la hauteur des pierres du d versoir au dessus du rev tement la minimisation de cette hauteur r duit la quanti...

Страница 13: ...PDM Une autre couche de sous couche peut tre ajout e au dessus du liner pour plus de s curit avant la pose de l Eco Blox Les sommets de l Eco Blox doivent tre de niveau REMARQUE Pour de meilleurs r su...

Страница 14: ...s le Vo te Choisissez l un des points de forage pour installer un remplissage automatique AF1000 en option voir le manuel 14 D BORDEMENT RACCORD D TAPE AF1000 REMPLISSAGE AUTOMATIQUE Installation PV15...

Страница 15: ...e personnaliser la taille des tubes et les emplacements des orifices pour n importe quelle application avec plusieurs points de per age et des panneaux plats Le haut du Vo tes accueille le remplissage...

Страница 16: ...es vis doivent seulement tre bien ajust es pour que le silicone fasse un joint Appliquez du silicone sur les filetages de l adaptateur pour filetage m le MTA Vissez le MTA dans l entr e jusqu ce qu il...

Страница 17: ...pompe Des emplacements de montage sont pr vus de chaque c t du PV7500 Suivez les instructions de remplissage automatique pour l installation Excavation et installation de PV7500 Le syst me Eco Rise L...

Страница 18: ...1mm au rep re Perfect Cut sp cifi pour la pompe utilis e acez la Vo te de Pompe dans la poche profonde puis installez l Eco Blox Le haut du champ de blocs doit tre de niveau Tirez la doublure bien aju...

Страница 19: ...e situ environ 1 38mm 2 51mm au dessus du niveau d eau de fonctionnement normal de l tang Garantie Tous les Vo tes de Pompe et FastFalls Atlantic sont garantis vie Cette garantie est tendue uniquement...

Страница 20: ...greso al dep sito para completar el ciclo La cantidad de agua necesaria para completar este ciclo es el volumen de agua en transici n Si el dep sito es demasiado peque o el arroyo es demasiado grande...

Страница 21: ...el arroyo lo m s peque o puede ser el dep sito La construcci n adecuada del cauce puede reducir la cantidad de agua necesaria Dado que el volumen de transici n est determinado por la altura de las pi...

Страница 22: ...rior del Eco Blox debe estar nivelada NOTA Para obtenerlos mejores resultados instale la bombayelAutollenado opcional antes de instalarla C mara en el dep sito siguiendo las instrucciones de las sigui...

Страница 23: ...I N ESCALONADA AF1000 LLENADO AUTOM TICO Instalaci n de tuber as en la C mara de Bombas PV1700 La PV1700 es la C mara de Bomba m s compacta y f cil de instalar de Atlantic El PV1700 cuenta con un reci...

Страница 24: ...aceptan mamparas de 3 76mm para drenajes de desechos y aplicaciones de plomer a personalizadas Decida la configuraci n que mejor se adapte a la aplicaci n luego instale la bomba las tuber as y el llen...

Страница 25: ...solo necesitan estar ajustados para que la silicona selle Aplique silicona en las roscas del adaptador de rosca macho MTA Atornille el MTA en la entrada hasta que quede apretado Use pegamento PVC no...

Страница 26: ...ciones de montaje se proporcionan a ambos lados del PV7500 Siga las instrucciones del Autollenado para instalar Excavaci n e Instalaci n de PV7500 El Sistema Eco Rise El tama o del dep sito depende de...

Страница 27: ...egue 2 51mm a la marca corte exacto especificada para la bomba que se est utilizando PV1700 PV7500 PV15000 TT1500 B B H TT2000 B B H TT3000 B B H TT4000 B B H TT5000 0 0 5 TT6000 0 0 5 TT7500 N A N A...

Страница 28: ...l producto completo debe devolverse al lugar de compra acompa ado del recibo original KIT DE LLENADO AUTOM TICO AF1000 Se han proporcionado puntos de perforaci n o reas planas para la ubicaci n correc...

Отзывы: