Atlantic Ultraviolet G48HO Скачать руководство пользователя страница 10

10

u

nit

 P

laCement

•  The 

Sanidyne

®

 

Plus

 is intended for indoor use only. The 

Sanidyne

®

 

Plus

 should be protected from liquid intrusion such 

as dripping water, condensation or mist, and used only in a clean, dry location with temperature ranges between 40 °F to 95 °F.

• 

Electrical power supplied to the 

Sanidyne

®

 

Plus

 must match power requirements listed on the 

Sanidyne

®

 

Plus

.

• 

The 

Sanidyne

®

 

Plus

 is intended for use in UNOCCUPIED AREAS ONLY

. Under no circumstances 

should this sanitizer be permitted to operate with humans, plants, or animals present in the Operation Area

.

• 

The intrusion sensors will detect movement if anyone is in the treatment area and the lamps will be switched off until fixture is 

reset by pressing the 

START/STOP

 button on keypad on the top of the 

Sanidyne

®

 

Plus

.

• 

For maximum efficiency the 

Sanidyne

®

 

Plus

 should be located as centrally as possible, away from the corners of the 

treatment area. The 

Sanidyne

®

 

Plus

 Portable Area Sanitizer is most effective when it is located in the vertical center of the 

room and the ultraviolet rays are unobstructed.

UNIT OPERATION 

P

re

-o

Peration

1. 

Fully charge the Hand-held Remote Controller (Shown in

 Figure 4

). 

NOTE:

 Charger provided operates on 100 volt to 240 

volts 50/60Hz and has a NEMA 1-15 plug.

2.  Once a location has been chosen for the 

Sanidyne

®

 

Plus

 post Laminated Warning Signs

 supplied with the 

Sanidyne

®

 

Plus

 on all access doors to the area where treatment operation will take place.

It is the users responsibility to post signs, or notices for all personnel and persons in the building or facility 

so that they be made aware that the Operation Area is off limits during treatment. 

3. 

 Connect the 

Sanidyne

®

 

Plus

 to a properly grounded outlet power source which matches the power requirements listed 

on the 

Sanidyne

®

 

Plus

 (See Power In location shown on 

Figure 2

- Rear View of Unit)

Approved 

Promate

™ 

Face Shields (2), are supplied with each unit. 

Promate

™ 

Face Shield MUST be 

worn prior to the next step by the operator as well as anyone else in the operation area. In addition the 

operator and anyone present MUST

 use protective gloves and clothing to protect skin from UV rays.

 

4. 

Turn power on using the Power Switch located on the rear of the 

Sanidyne

®

 

Plus

 (See Power Switch location shown on 

Figure 2 – Rear View of Unit

). Switch will glow 

RED

 when power is on. Once fixture receives power, the 

RED

 lights 

located just below the Occupancy Sensors on the top of the fixture will glow 

RED

. (See Occupancy Sensors (4-Total), shown 

on 

Figure 1 – Dimensional Data

). This is not a warning, it indicates that the sensors are aware of your presence. 

Step 4

 

 Using the lamp, apply 

slight pressure to compress the lower 

lampholder, and then pivot the lamp so 

it aligns with the top lamp socket. Lamp 

should appear straight when it is correctly 

in place. Confirm pins are inserted and 

that both ends align. As shown above, 

adjust each lamp socket if there is any gap 

between the lamp base and lamp socket.

Step 5

 

 Repeat until all lamps 

have been installed.

Step 6

 

 Once complete, reinstall 

Top Cover.

Содержание G48HO

Страница 1: ...tructions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Ultraviolet com BuyUltraviolet com Extensive Product Information Available at Ultraviolet com BuyUltra...

Страница 2: ...S 16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Plus Portable Area Sanitizer Questions that are not specifically answerable by these instructions should be directed to the factory Atlantic Ultraviolet Corporation takes all possible precautions when packag...

Страница 3: ...13 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit The following conventions are used to indicate and classify precautions in this manual and on product safety labeling Failure to observe precautions could result in injury to people or ...

Страница 4: ... and validate the suitability of this equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should periodically inspect clean as necessary and confirm the presence and good legibility of the product safety labels Contact the...

Страница 5: ...ration The Sanidyne Plus design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent areas and surfaces from microorganisms The ultraviolet disinfection dosage is a function of time and the intensity of the ultraviolet radiation to which the air and surrounding surfaces are exposed NOTE The Sani...

Страница 6: ...inspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Plus is assembled checked and confirmed The Sanidyne Plus Portable Area Sanitizer includes 1 Eight lamp fixture with power cord Includes a microprocessor controller with time display and push button controls 1 Hand Held Remote Controller 8 STER L RAY High Out...

Страница 7: ...Start Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during Treatment Time Flashes rapidly if occupancy sensor is tripped TREATMENT TIME POWER MINUTES HOURS START STOP Treatment Time Displays HOURS MINUTES 1 Hours Button Up and Down Arrows set time from 0 to...

Страница 8: ...ute and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time begins the word run flashes and when the treatment time is completed the word donE will appear 6 Return Button Brings you back to previous screen Remote Overview Continued on Page 9 Lamp operation i...

Страница 9: ...ller 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Home screen pressing and holding this button will bring up a menu with choices to Power Off Reboot Airplane Mode ON OFF MUST BE SET TO ON AT ALL TIMES Additionally displays three icons at bottom which ...

Страница 10: ...ent operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is off limits during treatment 3 Connect the Sanidyne Plus to a properly grounded outlet power source which matches the power requirements listed on the Sanidyne Plus See Power In location shown on Figure ...

Страница 11: ... than 30 seconds remain on the countdown time the Sanidyne Plus will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area of the Sanidyne Plus Under no circumstances should this sanitizer be permitted to operate with humans plants or animals present in the Operation Area 4 Outside the Operation Area the Treatment Time can...

Страница 12: ...he display or at the Sanidyne Plusby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Plus the operator can reset the fixture by pressing the START STOP button on the keypad controller again to begin the 1 30 countdown to allow all inhabitants to leave the area After the 1 30 has elapsed the Sanidyne Plus will power on and complete the remaining Treatment Time left ...

Страница 13: ...able etc 2 Measure the longest distance from the Sanidyne Plus to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if the distance from your fixture measures 15 feet find the 15 foot mark on the bar chart for each time range As the treatment time increase dose increases NOTE The number at the end of each bar is the expect...

Страница 14: ... AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Plus have ArmorLiteTM Safety Shield which is a protective covering over the glass of the lamp DO NOT REMOVE this covering Always disconnect power to the fixture before performing any service or maintenance Germicidal lamps are easily damaged Exercise care when han...

Страница 15: ...properly seated Check lamp socket and re install lamp if necessary Loose Connection Inspect for loose or disconnected wires Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Plus fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shield enter area and disconnect power to unit Call factory for technical service ...

Страница 16: ...d can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm that your Sanidyne Plus is achieving the desired UV C exposure Each card is designed for one 1 treatment cycle and CANNOT be reused Complete instructions for use are on back of card One 1 card has been incl...

Страница 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 20: ...lied including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury to person damage to or loss of property or value caused by any product which has been subjected to misuse negligence accident or modified or repaired by unauthor...