background image

2

TABLE OF CONTENTS

SAFETY WARNINGS .....................................................................................................................................................................3
SAFETY INSTRUCTIONS ............................................................................................................................................................3
SAFETY LABELING ......................................................................................................................................................................3
CAUTION ..........................................................................................................................................................................................4
PRODUCT APPLICATION ...........................................................................................................................................................4

Construction

 ..................................................................................................................................................................................................

4

Principle of Operation

 .................................................................................................................................................................................

4

Limitation of Use

 ............................................................................................................................................................................................

4

Water Quality

 .................................................................................................................................................................................................

4

INSTALLATION ..........................................................................................................................................................................5–8

Location

 ........................................................................................................................................................................................5

Dimensional Data

 .........................................................................................................................................................................5

Recommended Installation

 .........................................................................................................................................................6

Installation: 

BIO 1.5 and BIO 3.0 120v 50/60Hz (ballast no.10-0518A)

 ........................................................................ 7-8

Installation: 

BIO 1.5 and BIO 3.0 230v 50/60Hz (ballast no.10-0514A)

 ........................................................................ 7-8

Recommended Options

 .................................................................................................................................................................8

MAINTENANCE .......................................................................................................................................................................9–13

Inspection

......................................................................................................................................................................................9

Lamp Installation or Replacement: 

BIO 1.5 and BIO 3.0 120v 50/60Hz (ballast no.10-0518A)

 ...................................10

Lamp Installation or Replacement: 

BIO 1.5 and BIO 3.0 230v 50/60Hz (ballast no.10-0514A)

 ...................................10

Quartz Sleeve Installation, Cleaning or Replacement

 ......................................................................................................11

Replacement of Broken Quartz Sleeve

 .................................................................................................................................12

Disposal of Mercury Added Lamp

 ...........................................................................................................................................13

TROUBLESHOOTING

 ................................................................................................................................................................13

TECHNICAL SPECIFICATIONS

 ..............................................................................................................................................14

OPTIONAL ACCESSORIES .......................................................................................................................................................14
REPLACEMENT PARTS .............................................................................................................................................................15
USER ASSISTANCE .....................................................................................................................................................................

16

Patent Notice

 .............................................................................................................................................................................16

WARRANTY & PRODUCT REGISTRATION .......................................................................................................................

16

These instructions generally describe the installation, operation and maintenance of the 

Bio-Logic

®

 Ultraviolet Water Purifiers, 

Models BIO 1.5 and BIO 3.0 using ballast no. 10-0518A and 10-0514A. Questions that are not specifically answered by these 

instructions should be directed to the Factory.

Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect 

and report all damages. Do not install damaged equipment.
Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to prevent the loss of 

accessories, mounting hardware, spare parts or instructions.

The information and recommendations contained in this publication are based upon data 

collected by the Atlantic Ultraviolet Corporation

®

 and are believed to be correct. However, no 

guarantee or warranty of any kind, expressed or implied, is made with respect to the information 

contained herein. Specifications and information are subject to change without notice.

Содержание Bio-Logic BIO 1.5

Страница 1: ...Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticU...

Страница 2: ...Patent Notice 16 WARRANTY PRODUCT REGISTRATION 16 These instructions generally describe the installation operation and maintenance of the Bio Logic Ultraviolet Water Purifiers Models BIO 1 5 and BIO...

Страница 3: ...TLY hazardous situation which if not avoided WILL result in death or serious injury To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL sa...

Страница 4: ...ual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with...

Страница 5: ...er should always be located closest to the point of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As w...

Страница 6: ...6 Recommended Installation Figure 2 Recommended Installation...

Страница 7: ...ter be installed in line prior to the water purifier The sediment filter will stop or trap any particulates from entering the water purifier Particulates may cause damage to the quartz sleeve as well...

Страница 8: ...sensor is capable of operating an optional audio alarm and or solenoid valve 13 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 1...

Страница 9: ...actory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation An LED indicator light located on the ballast provides visual indicatio...

Страница 10: ...mber While holding lamp end remove lamp socket from exposed lamp end 4 Carefully withdraw lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleev...

Страница 11: ...hin the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the oppos...

Страница 12: ...o remove all quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the quartz sleeve with the gland fitting of the chamber 10...

Страница 13: ...he Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use...

Страница 14: ...special input power requirements Table 5 Optional Accessories Optional Accessories Available for SENTRY Safety Sensor BIO 1 5 BIO 3 0 Promate Time Delay Mechanism BIO 1 5 BIO 3 0 Promate Elapsed Time...

Страница 15: ...5 1366 R 05 1370 R 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 3023A 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 00 1023A 7 CRYSTAL CLEAR Quartz Sleeve 1 15 1700A 15 1701A 8 Cham...

Страница 16: ...bility and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury...

Отзывы: