background image

2                    

SP-8000 Subwoofer Preamplifier 

 

 

3

Instruction Manual

CAUTION:

 To reduce the risk of electric shock, do not remove the 

cover . No user serviceable parts inside. Refer to qualified personnel.

WARNING:

 To reduce the risk of fire or electric shock, do not expose 

this appliance to rain or moisture. This device generates a fair amount 
of heat. Make sure nothing blocks the ventilation openings on the top 
and bottom of the unit.

The lightning flash with arrowhead, within an equilateral 
triangle, is intended to alert the user to the presence of 
uninsulated “dangerous voltage” within the product’s 
enclosure that may be of sufficient magnitude to con-

stitute a risk of electrical shock to persons.
The exclamation point within an equilateral triangle is 

intended to alert the user to the presence of important 
operating maintenance (servicing) instructions in the 
literature accompanying the appliance.

For Future Reference

Record your product's serial numbers and date of purchase here:

Model Number                                                                              

Serial Number                                                                                

Date of Purchase

The serial number is found on the back panel. 

Table of Contents

Safety Precautions

Safety Precautions

IMPORTANT NOTE

These instructions are for Atlantic Technology Model SP-8000, 
which must be used with either a powered subwoofer or a sub-
woofer with external power amplifier.  The SP-8000 is a preampli-
fier controller only, it does not contain a power amplifier.

The SP-8000 can be used with virtually any amplified subwoofer sys-
tem which has either a balanced or unbalanced line-level input.

  3  SP-8000 Subwoofer Preamplifier
  4  SP-8000 Features

  4       Test and Training CD-ROM

  5  Preamplifier Front Panel
  6  Premplifier Back Panel
  7  Remote Control
  7  Connecting Your Preamplifier

  7       Input
  7       Output

  8  Basic Hookup
  9  Remote Control Connections

  9       Power Connection

 10  Subwoofer Placement

 10       Single Subwoofers
 10       Dual Subwoofers

 10  System Setup and Operation

 10       The Low Pass Control
 10       Bass Management
 11       The Phase Control
 11       Parametric Room Equalizer (EQ) 
 11       Adjusting the Parametric EQ Using a Meter or 

Real Time Analyzer (RTA)

 11       Setting the Parametric EQ Using an SPL Meter
 12       Level Setting Using an SPL Meter
 12       Level Setting Without an SPL Meter
 12       Setting the Subwoofer Level Without an 

SPL Meter or Test Tones

 12       How Much is Enough?

 12  Remote Control Functions
 13  Direct Access Connector
 13  Care of Your SP-8000 System
 13  Troubleshooting Guide
 14  Specifications
 15  Program EQ Setting Curves

Copyright © 2003 Atlantic Technology International.
Specifications are those in effect at the time of printing. Atlantic Technology reserves the 

right to change specifications or designs at any time without notice. THX and THX Ultra 2 

are registered trademarks of Lucasfilm, Ltd. Dolby Digital, AC-3, Dolby Stereo and Dolby 

Pro Logic are trademarks of Dolby Laboratories Licensing Corporation. 

Содержание SP-8000

Страница 1: ...SP 8000 Subwoofer Preamplifier High Performance Customized Bass Management For Any Freestanding Amplified Subwoofer SP 8000 Subwoofer Preamplifier Instruction Manual Your Subwoofer...

Страница 2: ...ampli fier controller only it does not contain a power amplifier TheSP 8000canbeusedwithvirtuallyanyamplifiedsubwoofersys tem which has either a balanced or unbalanced line level input 3 SP 8000 Subwo...

Страница 3: ...itybringsnewmeaning to the terms system and room integration providing unheard of fine tuning capability to optimize its your subwoofer s performance as well as increase your own enjoyment This system...

Страница 4: ...ents Four position Phase Invert switch pages 5 11 and 12 Allows precise acoustic matching with satellite speaker systems whose output may be phase reversed Can also help to compensate for unusual room...

Страница 5: ...rence or EQ program as applied via the remote control page 11 12 MUTE indicator Lights when amplifier volume is muted via the remote control page 7 and 13 PHASE control SetscorrectSubwooferphase 0 90...

Страница 6: ...rol Use the OUT TO SLAVE jack to pass on the received signal to other equipment Low Level jacks Usetheinputjacktoconnecttothe subwoofer or LFElineout from your processor receiver Use the output jack t...

Страница 7: ...er manual for fur ther information regarding the use of these outputs If possible use the XLR type input balanced Output Connect a high quality shielded cable from here to the input of your subwoofer...

Страница 8: ...re registered trademarks of THX Ltd EQ 2 COMMAND VOL VOL MUTE REF EQ 1 EQ 4 EQ 5 EQ 3 COM OUT TO DATA 12 V GND SLAVE EXT IR RCVR INPUT OUTPUT AC INPUT 16 V 50 60 Hz SLAVE IR IN THRU MODEL SERIAL NUMBE...

Страница 9: ...D AND ENGINEERED IN USA AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISKOFELECTRICSHOCK WARNING DONOTOPEN Power Connection ConnecttheSP 8000 spowersupplyunittoanACoutletonlyaftermak ingallotherconnec...

Страница 10: ...in crossover If your processor is THX certified or has a built in crossover bypass the Preamplifier s amplifier s LOW PASS control by setting it to the THX EXT setting AllTHXcertifiedsatelliteshavebe...

Страница 11: ...home theater in addition to the test tones Although the test tones can be used to set the Room EQ by ear we very strongly recommend using a Sound Pressure Level meter or a Real TimeAnalyzer to set th...

Страница 12: ...an SPL Meter or Test Tones Start your listening with the SP 8000 s LOW PASS control set at the rec ommendedcrossoverpoint orintheTHX EXTpositionif you reusinga THXCertifiedprocessororunitwithabuilt in...

Страница 13: ...urewillresultincontinuousstepstothemaximumof 10dB The REF EQ and REF volume reset functions each have their own set of contacts Care of Your SP 8000 The preamplifier can be wiped with a clean dry clot...

Страница 14: ...ut Total Harmonic Distortion 03 full output Low Level Input Sensitivity 250mv full output 100Hz Low Level Input Impedance 22K Output Level 3 V max Output Impedance 150 Dimensions W x H x D in cm 16 87...

Страница 15: ...tting Curves EQ1 EQ2 EQ3 EQ4 REF THX flat Note These graphs represent the response of a typical THX Ultra 2 Subwoofer System without crossovers In actual use the system is not designed to respond beyo...

Страница 16: ...16 SP 8000 Subwoofer Preamplifier 343VanderbiltAvenue Norwood MA 02062 781 762 6300 www atlantictechnology com 015 1866...