Operation & Troubleshooting

is less sensitive at the frequency extremes (deep bass and very high 
sounds). In order to compensate when you must play the system at lower 
volume levels, EQ4 has been designed to raise the overall bass output of 
the sub slightly. The result will be a fuller and richer sounding bass at low 
volumes. EQ4 is designed for both music and movies. It can also be used 
to help compensate for lack of bass at the listening position.

REF

 - This resets the EQ to flat response and the also resets the volume 

trim to 0dB.

LEVEL  TRIM  and  MUTE

 

-  The 

  and 

  buttons  let  you 

change  the  total  output  level  of 
your subwoofer to compensate for 
soundtrack variations and your per-
sonal preferences. Each push of the 

button results in a 1dB change above or below the preset reference set 
with the BASS LEVEL control. The LEVEL TRIM readout on the ampli-
fier indicates the level of adjustment in dB.
Pressing the MUTE button turns off the volume of the Subwoofer. Press-
ing it again returns the volume to its previous setting.

Direct Access Connector

Located on the rear panel, this port and the corresponding male plug 
(shipped installed in the port) is for use with a hard wired remote control 
system using electronic or mechanical switching. Each contact function 
is labeled. To access the control functions use a normally open connec-
tion. Momentary closure will activate each function. The LEVEL TRIM 
function will respond in 1dB steps to a single contact closure while con-

stant closure will result in continuous steps to the maximum of ± 10dB. 
The REF EQ and REF volume reset functions each have their own set 
of contacts.

Care of Your SP-8000

The preamplifier can be wiped with a clean, dry cloth. If necessary, you 
can clean the front panel with a soft cloth moistened with mild window 
cleaner or dampened 

slightly

 with water.

IMPORTANT: SAVE YOUR BOXES! 

If you can do so, save the car-

ton, packing pieces and plastic bags that came with your SP-8000. 
They will be useful in case you move or have to ship your system 
for any reason. In any case, save all packing materials until you are 
certain that the system has suffered no damage in shipment. If you 
find such damage, either visible or internal, contact your dealer 
immediately for the proper return procedure.

Troubleshooting Guide

Once your Preamp is set up, you should have many years of maintenance 
free enjoyment from your system. However, if you should encounter a 
problem, refer to the following guide to help find the solution. If the prob-
lem persists, please contact your local authorized Atlantic Technology 
dealer.

���

���

���

���

���

����

����

Problem 

Possible Cause 

Possible Solution

No bass output 

AC power cord unplugged or  

Plug into a working outlet.

 

plugged into a non-working outlet. 

 

Input cables not securely  

Check all connections, then try another 

 

connected or defective. 

input cable.

Audible buzz or hum  

Input cable not securely connected  

Check all connections, then try another 

 

or defective. 

input cable.

 

Ground loop through antenna or  

Test by disconnecting antenna and/or cable 

 

cable TV system input. 

system input leads. If hum goes away, install 

 

 

isolation balun(s) at that point.

Содержание SP-8000

Страница 1: ...SP 8000 Subwoofer Preamplifier High Performance Customized Bass Management For Any Freestanding Amplified Subwoofer SP 8000 Subwoofer Preamplifier Instruction Manual Your Subwoofer...

Страница 2: ...ampli fier controller only it does not contain a power amplifier TheSP 8000canbeusedwithvirtuallyanyamplifiedsubwoofersys tem which has either a balanced or unbalanced line level input 3 SP 8000 Subwo...

Страница 3: ...itybringsnewmeaning to the terms system and room integration providing unheard of fine tuning capability to optimize its your subwoofer s performance as well as increase your own enjoyment This system...

Страница 4: ...ents Four position Phase Invert switch pages 5 11 and 12 Allows precise acoustic matching with satellite speaker systems whose output may be phase reversed Can also help to compensate for unusual room...

Страница 5: ...rence or EQ program as applied via the remote control page 11 12 MUTE indicator Lights when amplifier volume is muted via the remote control page 7 and 13 PHASE control SetscorrectSubwooferphase 0 90...

Страница 6: ...rol Use the OUT TO SLAVE jack to pass on the received signal to other equipment Low Level jacks Usetheinputjacktoconnecttothe subwoofer or LFElineout from your processor receiver Use the output jack t...

Страница 7: ...er manual for fur ther information regarding the use of these outputs If possible use the XLR type input balanced Output Connect a high quality shielded cable from here to the input of your subwoofer...

Страница 8: ...re registered trademarks of THX Ltd EQ 2 COMMAND VOL VOL MUTE REF EQ 1 EQ 4 EQ 5 EQ 3 COM OUT TO DATA 12 V GND SLAVE EXT IR RCVR INPUT OUTPUT AC INPUT 16 V 50 60 Hz SLAVE IR IN THRU MODEL SERIAL NUMBE...

Страница 9: ...D AND ENGINEERED IN USA AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISKOFELECTRICSHOCK WARNING DONOTOPEN Power Connection ConnecttheSP 8000 spowersupplyunittoanACoutletonlyaftermak ingallotherconnec...

Страница 10: ...in crossover If your processor is THX certified or has a built in crossover bypass the Preamplifier s amplifier s LOW PASS control by setting it to the THX EXT setting AllTHXcertifiedsatelliteshavebe...

Страница 11: ...home theater in addition to the test tones Although the test tones can be used to set the Room EQ by ear we very strongly recommend using a Sound Pressure Level meter or a Real TimeAnalyzer to set th...

Страница 12: ...an SPL Meter or Test Tones Start your listening with the SP 8000 s LOW PASS control set at the rec ommendedcrossoverpoint orintheTHX EXTpositionif you reusinga THXCertifiedprocessororunitwithabuilt in...

Страница 13: ...urewillresultincontinuousstepstothemaximumof 10dB The REF EQ and REF volume reset functions each have their own set of contacts Care of Your SP 8000 The preamplifier can be wiped with a clean dry clot...

Страница 14: ...ut Total Harmonic Distortion 03 full output Low Level Input Sensitivity 250mv full output 100Hz Low Level Input Impedance 22K Output Level 3 V max Output Impedance 150 Dimensions W x H x D in cm 16 87...

Страница 15: ...tting Curves EQ1 EQ2 EQ3 EQ4 REF THX flat Note These graphs represent the response of a typical THX Ultra 2 Subwoofer System without crossovers In actual use the system is not designed to respond beyo...

Страница 16: ...16 SP 8000 Subwoofer Preamplifier 343VanderbiltAvenue Norwood MA 02062 781 762 6300 www atlantictechnology com 015 1866...

Отзывы: