ATL TELECOM USER GUIDE
AM2048A OS/OM
21
4.8.1.3
G.703 to X.21/V.35 Internal Timing
Slave terminals are connected to the digital section at both ends, a clock inside the Master
then becomes the reference clock for the entire system.
The internal clock is generated at the ELU, both terminals lock to this clock and return the
clock to the AM2048s. An elastic store in the AM2048 buffers the data.
Using the “Configuration > User Port” Menu:
At the Master, select the ‘Internal’ timing option (There is nothing to set at the Slave).
Press ‘Return’ to enter the changes.
4.8.1.4
X.21/V.35 DCE to X.21/V.35 DCE
The terminals connected to the digital section at both ends are DTEs, a clock inside the ELU
then becomes the reference clock for the entire system.
V35/X.21
DTE
AM2048
Slave
AM2048
Master
Terminal
Terminal
V35/X.21
DCE
V35/X.21
DCE
V35/X.21
DTE
B
B
AM2048
Slave
AM2048
Master
Terminal
Terminal
B
B
G.703
G.703
V.35/X.21
V.35/X.21
DTE
DCE
4
20
ATL TELECOM USER GUIDE
AM2048A OS/OM
Using the “Configuration > User Port” Menu:
1
At the ELU, select the ‘Transparent’ timing option.
2
Using F8, cycle to the NTU user port, select the ‘Transparent’ timing option.
Press ‘Return’ to enter the changes.
Note
: This is the default timing option for G.703.
4.8.1.2
G.703 to G.703 Internal Timing
Slave terminals are connected to the digital section at both ends, the clock source inside the
Master then becomes the reference clock for the entire system.
The internal clock is generated at the Master, both terminals lock to this clock and return the
clock to the AM2048s. An elastic store in the AM2048 buffers the data.
Using the “Configuration > User Port” Menu:
1
At the Master, select the ‘Internal’ timing option.
2
Using F8, cycle to the NTU user port, select the ‘Internal’ timing option.
Press ‘Return’ to enter the changes.
G.703
AM2048
Slave
AM2048
Master
Terminal
Terminal
G.703
G.703
G.703
B