When selecting the correct amperage rating for your in-line circuit breaker, first determine the
maximum current output of your solar panel array by adding up the current at maximum Power (Imp)
for each panel, then round up to the next standard amperage size.
Example: (3) 150watt panels, Imp = 8.5Amps ea. Total Imp. = 25.5Amps
Recommended fuse or circuit breaker size 30 Amps.
In-line Fuse examples (Resettable or Blade type)
Bussman Maxi in-line fuse holder
Part number: HHX (6 Awg wire)
Bussman Maxi Fuse
Available in 20, 25, 30, 35, 40 & 50 Amps
Part number: CB185-XX
XX= Amp rating
Bussman Resettable Circuit Breaker
Available in 20, 25, 30, 35, 40 & 50 Amps
XX=Amp rating
Automotive Audio Resettable Breaker
Available in 20, 30, 40 & 50 Amps
The fuse, fuse holder and circuit breakers are available at any of the major on-line retailers.