Charging Mode LED Definitions 

 

The Charge Mode LED indicates which of the three main PWM charge stages the controller is in: 

 

Bulk charge stage - The LED is lit red 

 

Absorption charge stage - The LED blinks red 

 

Float charge stage - The LED is lit green 

If  the  charge  mode  LED  is  not  lit,  it  means  that  there  is  not  enough  sun  light  to  charge  the  battery, 

controller is in night mode. 

Charge Type LED Definitions 

 

The charge type LED indicates the types of charge the controller is in: 

Soft Charge - The LED is lit red.  

 

Soft charge is set when the battery voltage drops below 11.0VDC. 

 

Once battery voltage climes above 11.5VDC it turns off. 

Equalization Conditioning - The LED blinks blue. 

 

Equalization flag is set when the battery voltage drops below 12.1VDC three times in a 14 day 

period. 

 

It is continuously lit while in equalization mode. 

Auto Boost - The LED blinks magenta when the auto boost flag is set. 

 

It is continuously lit during the bulk and absorption phase of the boost cycle. It turns off once the 

controller returns to float stage. 

The charge type LED is not normally lit, if any of the above conditions occurs, it will then blink or light 

continuously, indicating the charge it’s in. 
While in the float charge stage, if the load currents exceeds the solar charge current and the controller 

can’t maintain the float voltage, the charge mode LED will blink green. If the battery voltage drops below 

13VDC for 5 minutes the controller sets its auto boost flag and blinks the charge type LED magenta. Once 
the load is reduced or the solar charge current increases and battery voltage returns to float voltage, the 

charge type LED turns on, until it completes the auto boost charge cycle. 

Battery Status LED Definitions 

 

The battery status LED indicates six levels of charge: full, high, medium, partial, low and empty. 

 

 

COLOR 

POWER 

BATTERY SOC 

VDC 

 

Lit Green 

Full 

100% 

>12.8 

  Blinking Green  High 

95 to 70% 

12.8 down to  

12.4 

 

Lit Orange 

Medium 

70 to 50% 

12.4 down to 12.1 

 

Blinking Orange 

Partial 

50 to 30% 

12.1 down to 11.8 

 

Lit Red 

Low 

30 to 10% 

11.8 down to 11.5 

 

Blinking Red 

Empty 

0% 

<11.5 

Содержание PVCM40D-MPT

Страница 1: ...MPT 40Amp Charge Controller Display Kit Part PVCM40D MPT SEDM6 40 SUNEXPLORER II MPT Manufactured by Atkinson Electronics Inc...

Страница 2: ...tery Type Selection Switch 8 Charging Mode Definitions 9 Charge Type LED Definitions 9 Battery Status LED Definitions 9 Charging Stage Descriptions 10 Charging Stage Descriptions Continued 11 Wiring D...

Страница 3: ...www atkinsonelectronics com Circuit Board Division 800 261 3602 Revised 05 19 Features PVCM40D SEDM6 40 1...

Страница 4: ...Battery status LED indicates the level of charge 6 levels from full to empty SEDM6 40 Display Processor Microprocessor controls all display and read out functions Battery Voltage Adjust P1 Displays b...

Страница 5: ...tors the battery voltage to know when the battery s have completed the bulk and absorption charging stages and has entered the float stage 3 It adjusts the PWM charge algorithms based on the varying l...

Страница 6: ...setting lock is activated The backlight will come on for 15 seconds any time the select button is pushed and will stay on continuously in scroll mode If a low battery voltage condition occurs the dis...

Страница 7: ...agram page 12 Keep the solar panels covered with an opaque material until wiring and setup is complete 4 Choose a location for the controller that is close to the battery location to minimize the volt...

Страница 8: ...l cause the controller to not work properly 2 When wiring the PV panel into the battery system adequate wire size must be used An 8 AWG wire for short distances and a 6 AWG or larger wire for longer d...

Страница 9: ...eline algorithm monitors the battery condition and will perform a conditioning charge provided the following requirements and conditions are met MINIMUM Imp of 12 Amps 2x 100 to 160 Watt solar panel a...

Страница 10: ...ED red and sets a soft charge flag blinking the charge type LED red and sets the battery equalization flag alternating between red and blue The controller then determines if there is enough solar volt...

Страница 11: ...t is continuously lit during the bulk and absorption phase of the boost cycle It turns off once the controller returns to float stage The charge type LED is not normally lit if any of the above condit...

Страница 12: ...t a constant voltage using PWM technology to finish charging the battery s to 100 of charge The controller uses Multi Point Tracking MPT to compensate for changing loads and solar conditions to mainta...

Страница 13: ...for lead acid AGM batteries Green Charge mode Stage 6 Auto Boost Charge The auto boost feature is as follows The controller is in float charge the trailer loads become greater than the solar charging...

Страница 14: ...www atkinsonelectronics com Circuit Board Division 800 261 3602 Revised 05 19 Wiring Diagram 12...

Страница 15: ...to the cabinet or mounting surface at the marked locations Use a Phillips screw driver to drive the screws into the mounting surface before mounting the display module Back out the screws cut out the...

Страница 16: ...um solar charge current the SEDM6 40 will indicate is about 0 30 Amps Below this value the SEDM6 40 will display chr if the PVCM40D MPT is passing solar charge current to the battery The current displ...

Страница 17: ...to battery remaining advance display to desired position then press and hold the button until the display flashes approximately 3 seconds 2 Release button when the display stops flashing it will remai...

Страница 18: ...e solar panel voltage is greater than 16VDC by measuring the voltage between PV and black wires with DC volt meter The solar panel wire polarity positive connected to the controllers PV bolt and the n...

Страница 19: ...1VDC AGM 14 3VDC Flooded wet 14 4VDC Lifeline 14 3VDC Accuracy 0 1VDC Float Voltage At room temperature 25 C 77 F Sealed Gel 13 3VDC AGM 13 5VDC Flooded wet 13 7VDC Lifeline 13 4VDC Accuracy 0 1VDC C...

Страница 20: ...ter height Battery Percent Display 12 8V 100 12 1V 50 11 5V 0 12V system Battery Voltage Displays 0 to 25VDC Low Battery Voltage Detects 11 8V Solar Voltage Displays 0 to 25VDC Current Display 0 to 25...

Страница 21: ...www atkinsonelectronics com Circuit Board Division 800 261 3602 Revised 05 19 Wire Size Recommendation Chart 19...

Страница 22: ...ple 3 150watt panels Imp 8 5Amps ea Total Imp 25 5Amps Recommended fuse or circuit breaker size 30 Amps In line Fuse examples Resettable or Blade type Bussman Maxi in line fuse holder Part number HHX...

Страница 23: ...ps Do not spray water or cleaning solution directly to the face plate or LCD of the SEDM6 40 The liquid could run between the face plate and the LCD on to the circuitry on the SEDM6 40 circuit board c...

Страница 24: ...kinsonelectronics com Circuit Board Division 800 261 3602 Revised 05 19 Make sure ALL of your connections from the solar panel to the battery are coated in dielectric grease Like Ideal Nolax or Permat...

Страница 25: ...ate of shipment by Atkinson Electronics Inc or its authorized distributors to the original customer Atkinson Electronics Inc will repair or replace at our option any defective products provided that o...

Отзывы: