Modbus slave mode
Modbus table:
Modbus address
Default values
Descriptions
60000
0
Octets 1 and 2 SIGFOX.
60001
0
Octets 3 and 4 SIGFOX.
60002
0
Octets 5 and 6 SIGFOX.
60003
0
Octets 7 and 8 SIGFOX.
60004
0
Octets 9 and 10 SIGFOX.
60005
0
Octets 11 and 12 SIGFOX.
60006
0
Write a 1 to send the 12 bytes to SIGFOX.
Note: This register is always read at 0
Note: In the ACW / 868-DINRS or ACW / 868-DINRS + version nothing will
happen, but the ACW will return a valid Modbus acknowledgment.
60007
0
(@Remote) Radio module address, from 0 to 255.
This is an advanced setting: Do not edit.
60008
255
(@Modem) Address of the remote radio module, from 0 to 255
(broadcast).
This is an advanced setting: Do not edit.
60009
1200,
Or
the
value
configured with the
configurator.
Baudrate radio, the possible values are:
1200
2400
4800
9600 or 9601 to activate the compatible mode.
19200 or 19201 to activate the compatible mode.
38400
57600
Note: Not all values are possible depending on the radio channel and the
selected transmission power.
60010
522,
Or
the
value
configured with the
configurator.
Canal radio, from 160 to 599.
Note: All values are not possible depending on the radio rate and the
chosen transmission power.
60011
255
Transmitting power - the possible values are: