![ATIM Cloud Wireless ACW/868-DINRS Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/atim/cloud-wireless-acw-868-dinrs/cloud-wireless-acw-868-dinrs_user-manual_2999343015.webp)
15
ATIM_ACW-D_UG_EN_V1.5
c.
Bridge mode configuration (LoRaWAN)
Attention
Setup available for LW8 (LoRaWAN) references Software 1.7 Revision A.3 or prior.
The following information applies to the ACW / LW8-DINRS.
In this operating mode, the data of the serial link is transmitted directly to the LoRaWAN network.
Note:
Frames must not exceed 512 bytes.
✓
1: Serial parameters: The ACW-DINRS module has a serial link that you can set in RS232 or RS485
mode. You must also specify the speed (Baudrate) you want to use: 4800, 9600, 19200, 38400,
57600, and 115200 are available. The other default and non-configurable parameters are: 1 stop
bit, no parity, no flow control and 8 data bits.
✓
2: LoRa parameters: Check 'Enable OTAA' to activate the 'Over The Air Activation' mode. Uncheck
'Enable OTAA' to activate 'Activation By Customization' mode.