17
ATIM_ACW-TCR_UG_EN_V1.0
c.
Factory settings
Radio frame settings
-
Emission period of a radio frame: 10 minutes
-
Number of samplings: 1
-
History depth: 1
General settings
-
Emission period of the keep alive frame: 4 days
-
Timestamp: disabled
Sensor’s configuration
Probe 1 (physical)
-
State: enabled
-
Threshold: disabled
Probe 2 (virtual):
-
State: enabled
-
Inertial coefficient: 5
-
Threshold: disabled