ACW-MR2_QIG_FR_V2.5           - Complete technical manual available at www.atim.com 

 

4

 

5.

 

ATTACHING GAS METERS 

 
ATIM can provide a cable (ref. CAB/MTRGAZ1) with the following features to connect to gas meters 
with an IP40 M16 connector: 
6-wire shielded cable with a 20 AWG cross section and 2 metres in length. 

PIN 

COLOUR 

SIGNAL 

Brown 

Moni 

White 

GND 

 Monitoring 

Grey 

Meter 2 + 

Blue 

Meter 1 + 

Yellow 

GND 

 Meter 2 

Green 

GND 

 Meter 1  

 
 
 

6.

 

ATTACHING OPTICAL SENSOR IN 

‘ELEC’

 MODE 

 

The ACW/XXX-MR1-ELEC reference is delivered with a Fludia optical sensor (4-wire cable, 30 
centimetres in length).

  

IMPORTANT: 

The weight of the pulses is different at the sensor output (1 output pulse = 5 input 

light pulses). 
 

PIN 

COLOUR 

SIGNAL 

2

 

Black

 

Power supply

 

Red 

Meter 1 + 

Green 

GND 

 Meter 1 

Yellow 

GND 

 Power  

 
 

NOTE: In MR1-

ELEC mode, the ‘METER 1+’ signal must be connected to the ‘

CNTR 

1’ input.

 

Powering an external sensor will reduce the product’s

 lifespan. 

 

 

 

Female DIN connector, as seen from outside 

Содержание ACW-LW8

Страница 1: ...igital input voltage 3 6 Vmax Operating temperatures 25 C 60 C Radio power 25 mW 14 dBm Radio frequency 868 MHz Operated network Sigfox or LoRaWAN Power supply One or two 3 6 V lithium batteries Confi...

Страница 2: ...must open the casing in order to gain access to module s configuration switches and to the terminal blocks To do this insert a screwdriver into the slot and tilt it downward to lift the inside tab see...

Страница 3: ...the same direction as the first battery Start up phases From 0 to 3 sec bootloader From 3 sec to 8 sec configuration From 8 sec to 10 sec configuration is applied green LED flashes red LED flashes if...

Страница 4: ...r 1 5 Yellow GND Meter 2 6 Green GND Meter 1 6 ATTACHING OPTICAL SENSOR IN ELEC MODE The ACW XXX MR1 ELEC reference is delivered with a Fludia optical sensor 4 wire cable 30 centimetres in length IMPO...

Страница 5: ...been applied via downlink it will be used the next time the device restarts a Configuration with internal DIP switches The configuration is read at start up The table below lists the different modes...

Страница 6: ...ission if state change detected DI2 TRIGGER frame if contact changes Radio transmission on falling edge DI2 TRIGGER frame when contact is closed See Section 1 9 COMMENT ON DIGITAL MODE Radio transmiss...

Страница 7: ...link Protocol v1 1 used by all products in the ACW line describes how to perform the following actions Request a restart for ACW devices Obtain product information Request that factory settings be res...

Страница 8: ...ital mode with radio transmission on falling and rising edges 0x0C ELEC mode with readings every 10 minutes transmission once per hour 0x0D ELEC mode with readings every 30 minutes transmission every...

Страница 9: ...t send the command C1050A000001F4 via downlink because 500 1F4 in hexadecimal e Setting meter 1 and meter 2 The index of meters 1 and 2 can be set with a single command to any value you choose in the...

Страница 10: ...concatenated 48 30 Index 5 32bits Tref 50min Index 4 32bits Tref 40min Index 3 32bits Tref 30min Index 2 32bits Tref 20min Index 1 32bits Tref 10min Index 0 32bits Tref LoRaWAN Test frame 49 31 Index...

Отзывы: