ATIM ACW/LW8-TM1D-HP Скачать руководство пользователя страница 4

ATIM_ACW-TM1D-HP_UG_EN_V1.2 

Document version history 

Version 

Date 

Description 

Author 

0.1 

12/11/2015 

Created document 

YL 

0.2 

25/11/2015 

Created overview 

YL 

0.3 

18/05/2016 

Added network 

YL 

0.4 

02/06/2016 

Corrections 

YL 

0.5 

10/06/2016 

Corrections 

YL 

0.6 

12/12/2017 

Added downlink and energy saver mode 

CB 

0.7 

23/01/2018 

Update visuals for labels / Sigfox / ACW config 

YM 

1.0 

26/03/2018 

Error codes ad startup sequences 
pre decoding examples of received frames 

CB 

1.1 

24/10/2019 

Upgrade from TM2D to TM2D-HP (batteries 
modifi PCB unit  USB port) 

ER 

1.2 

09/01/2020 

Corrections 

MD 

 

Disclaimer 

The  information  contained  in  this  document  is  subject  to  change  without  warning  and  does  not  represent  a 

commitment on the part of ATIM radiocommunications. ATIM radiocommunications provides this document ‘as

-

is’ 

with no warranty of any kind, express or implied, including but not limited to implied warranties of merchantability or 
fitness for a particular purpose. ATIM radiocommunications may make changes and/or improvements to this manual 
or to the product(s) or program(s) described in this manual, at any time. 
 
 

Trademarks and copyright 

ATIM  radiocommunications®,  ACW  ATIM  Cloud  Wireless®  and  ARM  Advanced  Radio  Modem®  are  registered 
trademarks  of  ATIM  SARL  in  France.  The  other  trademarks  mentioned  in  this  document  are  the  property  of  their 
respective owners. 
 
 

 

Содержание ACW/LW8-TM1D-HP

Страница 1: ...ATIM Cloud Wireless Digital temperature sensor with contact probe TM1D HP User Guide Concerned models ACW LW8 TM1D HP ACW LW8 TM1D HP 5 ACW SF8 TM1D HP ACW SF8 TM1D HP 5...

Страница 2: ...the configuration tool 12 b Energy Saver mode 13 ACW configuration tool 14 a What version of the ACW configuration tool should you use 14 b Configuring the LoRaWAN network pairing mode 15 c Configurin...

Страница 3: ...Viewing probes on the ACW platform 22 b Registering the modem on the Sigfox network 23 c Registering the modem on the LoRaWAN network 26 Troubleshooting 27 The modem cannot be configured via USB or th...

Страница 4: ...Corrections MD Disclaimer The information contained in this document is subject to change without warning and does not represent a commitment on the part of ATIM radiocommunications ATIM radiocommuni...

Страница 5: ...d EN300 220 1 v2 4 1 Environmental recommendations a Explosive atmosphere Except for the ACW ATEX line specifically intended for this purpose do not use ACW radio modems in the presence of flammable g...

Страница 6: ...an Union This symbol appears on a product or its packaging to indicate that the product may not be discarded with another household waste Rather it is your responsibility to dispose of this product by...

Страница 7: ...65 Power supply 2x battery packs 14 4 Ah Weight 210 g Frequency 865 870 MHz Power 25 mW 14 dBm Transfer rate Sigfox 100 bps LoRaWAN 300 bit s to 10 kbit s Current draw Sigfox LoRaWAN Tx mode 60 mA 50...

Страница 8: ...7 ATIM_ACW TM1D HP_UG_EN_V1 2 Housing a Space requirements Maximum cable diameter through cable gland 7 mm...

Страница 9: ...lift the inside tab see photo Then pull on the back panel to separate the two parts of the housing c Mounting to a support ACW modems can be mounted on a flat wall a tube or pole or a DIN rail depend...

Страница 10: ...dems the communication keys are automatically provided by the network pairing via Over The Air Activation or OTAA Each ATIM ACW product line has a QR Code label visible either on the side or on the fr...

Страница 11: ...eading this code indicates the following information ATIM ACW XXX TM1D HP X X 190114 1 3 0 5 11 XXXXXXXXXXXXXXX Interpretation ATIM ACW XXX TM1D HP X X 190114 1 3 0 5 11 XXXXXXXXXXXXXXX Manufacturer n...

Страница 12: ...ot right against the wall ideally at least 20 cm away The cables must be no longer than 10 m and must be shielded For optimal results we recommend that you place it high up and at least 1 metre away f...

Страница 13: ...sent on a regular and periodic basis This makes it possible to obtain a very precise monitoring curve In this mode each reading is sent out by the ACW TM1D In other words the sampling period is equal...

Страница 14: ...r than the maximum value specified by the user If an alert threshold is crossed a frame is sent out when the temperature reading leaves or re enters the comfort zone Example of operation in Energy Sav...

Страница 15: ...www atim com download 7887 When the ACW Configuration Tool is started the stand by window appears on the screen Click Help at the top left of the window then click About to view the version number of...

Страница 16: ...time the module starts up or requests a connection This is the mode that is configured by default ABP Activation By Personalization In this mode the communication keys used are the ones loaded on the...

Страница 17: ...mode of operation Difference in C vs last reading sent If outside range send an alert Frequency of transmission to network Lower threshold Upper threshold Offset applied to each reading and to the di...

Страница 18: ...odic and Energy Saver modes LoRaWAN pairing OTAA Keep alive frame sent 1x day Temperature offset 0 C Lower threshold 20 C Upper threshold 40 C Parameter for periodic mode Sampling and statement period...

Страница 19: ...temperature value equals to 0x8000 indicates a measuring error This is often due to a loose cable b Example Example of frame received hex 2C0348 Frame type hex 2C 44 Higher threshold was crossed Digi...

Страница 20: ...y 10 min 0x05 every hour 0x0A every 2 hours 0x0B every 4 hours 0x0C every 8 hours 0x06 every day 0x0D every 2 days 0x0E every 3 days 0x0F every 4 days 0x07 every week 7 days 0x08 every month 30 days b...

Страница 21: ...ABP Activation By Personalization OTAA Over The Air Activation h Delta for comfort zone Parameter code Byte 1 Parameter value Byte 2 0x10 0xYY For a delta in C with a precision in tenths of a degree...

Страница 22: ...HP modem is equipped with an external digital temperature probe Number Signals to be wired Description 1 GND S1 Earth for probe 1 2 Power S1 Power for probe 1 3 Data S1 Data for probe 1 4 Nc nc 5 nc...

Страница 23: ...Viewing probes on the ACW platform Connect to the Web platform at http acw atim com to access all your devices and view your data Your login credentials will be emailed to you when we send out your o...

Страница 24: ...ox network If you have signed up with ATIM for a subscription to the Sigfox network we will take care of registering your modem probe sensor on the Sigfox network However if you have set up your subsc...

Страница 25: ...pen a Web browser and go to https backend sigfox com Enter the login name and password you selected when you created your Sigfox customer account Step 2 Click Device at the top left Step 3 On the scre...

Страница 26: ...in your Sigfox account Your product is now being imported to your Sigfox account The import may take several hours Sigfox identifier Sigfox PAC code Sigfox certificate number for your product provide...

Страница 27: ...rom a dropdown menu in the configuration tool interface We recommend that you use the simpler OTAA mode When configured in OTAA mode the device sends out a join request for a LoRa network when it is s...

Страница 28: ...correctly connected to the modem Check whether the modem has been registered on the network Check whether radio network coverage is available Check whether the blue and green lights flash during trans...