Electrical safety
Design of the connection cable according to IEC 60 245 (H 07 RN-F) with
a core cross-section of at least
−
1.5 mm² for cable lengths
up
to 25 m
−
2.5 mm² for cable lengths
over
25m
Long and thin connection lines result in a potential drop. The motor does
not reach any longer its maximal power; the function of the device is
reduced.
Plugs and coupler outlets on connection cables must be made of rubber,
plasticised PVC or other thermoplastic material of same mechanical
stability or be covered with this material.
Protect yourself against an electric shock. Avoid touching earthed parts
with your body.
The connector of the connection cable must be splash-proof.
Wind off completely the cable when using a cable drum.
13
Do not use the cable for purposes for which it is not meant. Protect the
cable against heat, oil and sharp edges. Do not use the cable to pull the
plug from the socket.
When running the connection line observe that it does not interfere, is not
squeezed, bended and the plug connection does not get wet.
Regularly check the extension cables and replace them if they are
damaged.
Do not use any defective connection cables.
When working outdoors, only use extension cables especially approved
and appropriately labelled for outdoor use.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current circuit breaker (30
mA).
The electrical connection or repairs to electrical parts of the machine
must be carried out by a certified electrician or one of our customer
service points. Local regulations – especially regarding protective
measures – must be observed.
Repairs to other parts of the machine must be carried out by the
manufacturer or one of his customer service points.
Use only original spare parts. Accidents can arise for the user through
the use of other spare parts. The manufacturer is not liable for any
damage or injury resulting from such action.
Assembling
Assembling the wheels
Push one wheel (1) on each side of the axle of the pre-assembled unit.
Secure them each with a washer and a screw.
[2 x screw M8x20,
2x washer A8.4]
Assembling the switch
Install the switch (17) onto the switch base (a).
Before the first start-up
To achieve flawless functioning of the machine, please follow the
instructions listed:
Place the saw at a location which meets following conditions:
−
outdoor
−
secured against slipping
−
free of vibrations
−
even
−
free of tripping hazards
−
adequate light
To ensure a safer foothold when working with the saw secure the saw
against rolling away.
Before each use, check
−
connection cables for defects (cracks, cuts, etc.)
Do not use any defective cables.
−
that the plastics inserts is in a proper condition
−
the saw blade for flawless condition
−
the functioning of the jigging device
Do not use any cracked saw blades or such that have changed their
shape.
Do not use any saw blades made of HSS steel.
Immediately replace a worn or damaged plastics inserts.
Assume the correct work posture. Stand in front of the operating side
frontally to the saw blade line.
Unlocking the transport safety device
Push the tilt table (2) towards the saw blade. The safety hook (3)
comes free.
Turn down the safety hook so that it rests on the axle.
Thanks to its return spring (11), the tilt table (2) automatically comes to
its home position.
Start-up
Rotational direction of the saw blade
Ensure that the rotational direction of the saw blade is the same as the
rotational direction given on the guard (19) .
You can change the direction by placing a screw-driver in
the slot provided in the plug collar, and adjust the correct
direction by moving to the left or right applying slight
pressure.
Selection of saw blades
Consider when selecting the saw blade, that no edgeless or damaged saw
bands are used and that the diameter of the blade location hole is 30 mm
(note the nameplate on the machine).
Mains connection
Compare the voltage given on the machine model plate e.g. 230 V with the
mains voltage and connect the machine to the relevant and properly earthed
plug.
Use a shockproof plug, mains voltage 230 V with residual current circuit
breaker (FI switch 30 mA).
Main fuse: 16 A inert