ATI Technologies GL6L Скачать руководство пользователя страница 19

Manual, Valve Adapters, Single Solenoid

Document #9620-20-C-Jxx Valve Adapters with a Single Solenoid-04

Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 • 

www.ati-ia.com

C-19

8.2  QC-310 Integrated Tool Changer Valve

3rd ANGLE PROJECTION

3

4

5

6

2

3

4

6

2

Exhaust Muffler

Ledge Mount

Ledge Mount

1/4" NPT Air Port See Table 1 for  Models

 31.8 

 67.4 

 158.8 

 22 

 8.8 

 30 

Solenoid Valve Cable

Single Solenoid

 50 

G 1/4 (BSPP)

Air Port (Adapter)

See Table 1 for Models

Valve Adapters with Single Solenoid and 1/4" NPT Air Port 

Valve Adapters with Single Solenoids and G 1/4 (BSPP) Air Ports

 

Notes:

Valve Adapter to Tool Changer mounting and Valve Connector sign

als are shown on Sheet 2.

1.

Pneumatic and Electrical Schematic are shown on Sheet 3.

2.

Other models are covered in the 9620-20-C-Jxx Valve adapter wit

h a Single Solenoid manual.

3.

Rev.

Description

Initiator

Date

04

Eco 18901; Added Air Filter 3490-0010005-01.  Changed Dim 14 to (50). Added Dim (30).

CF

4/2/2020

ITEM NO.

QTY

PART NUMBER

DESCRIPTION

1

3405-1030005-01

Fitting, Adapter, 1/4NPT to G1/4

2

1

3490-0010005-01

 Air Filter, 1/4 NPT Male X 1/4 NPT Female

3

1

3490-1010002-00

Conical Breather 1/8 NPT

4

2

3500-1064020-15A

M5-0.8 x 20mm SHCS, Blue, Pre-Applied

5

2

3500-1066020-15A

M6-1 x 20mm SHCS, Blue, Pre-Applied

6

1

9120-C-3PM-3PF-0016

3-Pin Pico Extension Cable, 0.16m Long

B

1:2

1

3

REVISION

NOTES:  UNLESS OTHERWISE  SPECIFIED.

DO NOT SCALE DRAWING.   ALL DIMENSIONS ARE IN  MILLIMETERS.

DRAWN BY:

CHECKED BY:

J. Handy, 1/7/16

W Berrocal, 9/9/16

TITLE

SCALE

SIZE

DRAWING NUMBER

PROJECT #

SHEET       OF 

9630-20-Jxx Single Solenoid for QC-310

 

04

PROPERTY OF ATI INDUSTRIAL AUTOMATION, INC. NOT TO BE REPRODUCE

D IN ANY 

MANNER EXCEPT ON ORDER OR WITH PRIOR WRITTEN AUTHORIZATION OF A

TI.

1031 Goodworth Drive, Apex, NC 27539, USA Tel: +1.919.772.0115      Email: [email protected] Fax: +1.919.772.8259      www.ati-ia.com ISO 9001 Registered Company

 

QC-310 Valve Adapters w/ Single Solenoid

Содержание GL6L

Страница 1: ...e Adapter Removal for QC 310 QC 313 QC 510 QC 1210 C 7 2 5 Tool Adapter Assembly Installation C 7 2 6 Tool Adapter Assembly Removal C 8 2 7 Pneumatic Connections C 8 2 8 Electrical Connections C 8 3 O...

Страница 2: ...113 QC 210 QC 213 GL6L GL7L 9121 JC3 M Single Solenoid 1 4 NPT QC 310 QC 313 QC 510 QC 1210 9121 JD2 M Single Solenoid G 1 4 BSPP QC 113 QC 210 QC 213 GL6L GL7L 9121 JD3 M Single Solenoid G 1 4 BSPP...

Страница 3: ...required for the Tool side The tool adapter assembly provides the proper spacing and a ledge mount for the control signal Tool module If the valve adapter on the Master has an air blow off feature th...

Страница 4: ...3 GL6L GL7L Tools required 5 mm hex key 3 mm hex key torque wrench Supplies required clean rag Loctite 222 Loctite 242 and Loctite 569 1 Place the Tool in a secure location 2 Uncouple the Master and T...

Страница 5: ...in Bottom of Valve Adapter Module 2 2 Valve Adapter Removal for QC 113 QC 210 QC 213 GL6L GL7L0 NOTICE Depending on maintenance or repair being performed utilities to modules and Master plate may need...

Страница 6: ...channel in the Tool Changer body so it will not get pinched when installing the valve adapter 6 Place the valve adapter on the Tool Changer or Utility Coupler 7 Apply Loctite 242 to the supplied M6 so...

Страница 7: ...Coupler refer to Figure 2 3 6 Make sure that the O rings are retained at the Master side Flat A mounting interface 2 5 Tool Adapter Assembly Installation Tools required 5 mm hex key 4 mm hex key torq...

Страница 8: ...2 4 2 7 Pneumatic Connections The air supply used for coupling and uncoupling the Tool Changer or Utility Coupler should be clean dry and non lubricated A supply pressure in the range of 60 to 100 ps...

Страница 9: ...he Tool Changer and Tool should be in a stand or storage location prior to actuation of the manual override It is important that the valve adapter be supplied with clean dry non lubricated air supplie...

Страница 10: ...ubleshooting Symptom Cause Resolution Tool Changer or Utility Coupler does not lock unlock or operates slowly Exhaust muffler is clogged Check replace exhaust muffler ensure clean air supply No or not...

Страница 11: ...is available to unlock the Master Do not execute the Latch command unless the Master and the Tool are ready to be coupled Tools required 3 mm hex key 2 mm ball end hex key 1 Using a 3 mm hex key remov...

Страница 12: ...to lock and unlock the Tool Changer Remove and check to make sure the exhaust muffler is not clogged Parts required Refer to Section 8 Drawings Tools required 11 mm hex wrench 1 Place the Tool in a se...

Страница 13: ...ings Supplies required Loctite 569 or similar Tools required 5 8 mm hex wrench 1 Place the Tool in a secure location 2 Uncouple the Master and Tool plates 3 Turn off and de energize all energized circ...

Страница 14: ...Single Solenoid Valve Adapters Refer to Section 8 Drawings for serviceable part for single solenoid valve adapters 6 2 Tool Adapter Assembly 1 2 3 Table 6 1 Tool Adapter Assembly Item Number Qty Part...

Страница 15: ...ections Solenoid Valve Connector M8 3 pin male with 0 16 m extension cable supporting latch and unlatch signals Electrical Rating 19 29 VDC operational voltage Solenoid Valve Current Draw Switched Pow...

Страница 16: ...id manual 3 Rev Description Initiator Date 04 Eco 18899 Added Air Filter 3490 0010005 01 Changed Dim 14 3 to 50 Added Dim 30 CF 4 14 2020 ITEM NO QTY PART NUMBER DESCRIPTION 1 1 3405 1030005 01 Fittin...

Страница 17: ...nd or storage location prior to actuation of the manual override NOTICE Actuation of valve override buttons requires very little travel 1mm and only a small amount of force Applying excess force can d...

Страница 18: ...is supplied It is critical that the exhaust mufflers are not restricted As part of a preventative maintenance 3 program periodically inspect and or replace the exhaust mufflers B 1 5 3 3 REVISION NOT...

Страница 19: ...escription Initiator Date 04 Eco 18901 Added Air Filter 3490 0010005 01 Changed Dim 14 to 50 Added Dim 30 CF 4 2 2020 ITEM NO QTY PART NUMBER DESCRIPTION 1 1 3405 1030005 01 Fitting Adapter 1 4NPT to...

Страница 20: ...to contingency situations The tool changer and associated tool should be in a stand or storage location prior to actuation of the manual override NOTICE Actuation of valve override buttons requires ve...

Страница 21: ...is supplied It is critical that the exhaust mufflers are not restricted As part of a preventative maintenance 3 program periodically inspect and or replace the exhaust mufflers B 1 5 3 3 REVISION NOT...

Отзывы: