PRODUCT  WARRANTY 

 
 

 

Analytical Technology, Inc. (Manufacturer) warrants to the Customer  that if any 

part(s)  of  the  Manufacturer's  equipment  proves  to  be  defective  in  materials  or 
workmanship within the earlier of 18 months of the date of shipment or 12 months of the 
date  of  start-up,  such  defective  parts  will  be  repaired  or  replaced  free  of  charge.  
Inspection and repairs to products thought to be defective within the warranty period will 
be  completed  at  the  Manufacturer's  facilities  in  Collegeville,  PA.    Products  on  which 
warranty repairs are required shall be shipped freight prepaid to the Manufacturer.  The 
product(s)  will  be  returned  freight  prepaid  and  allowed  if  it  is  determined  by  the 
manufacturer that the part(s) failed due to defective materials or workmanship. 
 
 

This warranty does not cover consumable items, batteries, or wear items subject 

to periodic replacement including lamps and fuses. 
 
 

Gas sensors carry a 12 months from date of shipment warranty and are subject 

to  inspection  for  evidence  of  misuse,  abuse,  alteration,  improper  storage,  or  extended 
exposure  to  excessive  gas  concentrations.    Should  inspection  indicate  that  sensors 
have failed due to any of the above, the warranty shall not apply. 
 
 

The  Manufacturer  assumes  no  liability  for  consequential  damages  of  any  kind, 

and  the  buyer  by  acceptance  of  this  equipment  will  assume  all  liability  for  the 
consequences of its use or misuse by the Customer, his employees, or others.  A defect 
within the meaning of this warranty is any part of any piece of a Manufacturer's product 
which shall, when such part is capable of being renewed, repaired, or replaced, operate 
to condemn such piece of equipment. 
 
 

This  warranty  is  in  lieu  of  all  other  warranties  (  including  without  limiting  the 

generality  of  the  foregoing  warranties  of  merchantability  and  fitness  for  a  particular 
purpose), guarantees, obligations or liabilities expressed or implied by the Manufacturer 
or its representatives and by statute or rule of law. 
 
 

This warranty is void if the Manufacturer's product(s) has been subject to misuse 

or abuse, or has not been operated or stored in accordance with instructions, or if the 
serial number has been removed. 
 
 

Analytical Technology, Inc. makes no other warranty expressed or implied except 

as stated above. 

Содержание C12-17

Страница 1: ...nology Inc ATI UK Limited 6 Iron Bridge Drive Unit 1 2 Gatehead Business Park Collegeville PA 19426 Delph New Road Delph Phone 800 959 0299 Saddleworth OL3 5DE 610 917 0991 Phone 44 0 1457 873 318 Fax...

Страница 2: ...PARTS LIST 19 C12 17 TRANSMITTER WITH DISPLAY SPARE PARTS LIST 20 TABLE OF FIGURES FIGURE 1 TYPICAL SYSTEM DIAGRAM ATI 0145 4 FIGURE 2 COMBUSTIBLE GAS SENSOR TRANSMITTER DIMENSIONS ATI 046 6 FIGURE 3...

Страница 3: ...in two versions one containing an integral display and single alarm relay and a second that is a simple blind transmitter with no display or alarm functions Gas sensors are housed in a corrosion resi...

Страница 4: ...VDC Display Optional 2 digit LCD Alarm Single setpoint or Trouble with SPDT 1A 125VAC 1A 30VDC alarm relay Temperature Limits 40 to 70 C Sensor Materials 316 Stainless Steel Enclosure Blind Galvanized...

Страница 5: ...ion system is to be activated within a few days of installation the cap should be removed when installation is complete Otherwise leave the cap in place until the system is to be placed in service Be...

Страница 6: ...rs contain two heated elements One of these elements is active and will allow combustible gases or vapors to burn on its catalytic surface The other is passive and does not react to gases These two el...

Страница 7: ...ngle conductor for the common of both the power supply and the output signal Figure 3 shows typical connections to a power supply and a panel indicator running off the 4 20 mA signal from the C12 17 t...

Страница 8: ...losure are factory wired as shown below However sensors can be supplied with up to 25 feet of cable for remote mounting The wiring diagram for the extended cable version is also shown below Extended c...

Страница 9: ...calibration adapter can be used with this system to allow gas to be fed from a point near the transmitter as shown in Figure 6 Figure 5 Dual Condulet Connections ATI 0579 EXPLOSION PROOF JUNCTION BOX...

Страница 10: ...00 LEL also differs for each gas While methane gas standards can always be used for calibration the value that the transmitter is adjusted to will vary depending on what type of gas the system is mean...

Страница 11: ...from the transmitter the absence of an combustible gases or vapors can be verified fairly easily The transmitter can also be set to zero using zero air available in cylinders Zero air cylinders and r...

Страница 12: ...gas cylinder is marked with a concentration of 2 5 Methane the calculation would be V 40 mV 160 mV X 2 5 V O 5 V O 120 mV When the span has been set turn off the span gas flow and remove the calibrat...

Страница 13: ...the system is meant to detect a gas or vapor other than methane A 1 methane gas standard may still be used for calibration of combustible transmitters when used for other gases However the voltage tha...

Страница 14: ...ver If the sensor does not respond it should be replaced SENSOR REPLACEMENT Combustible gas sensors used in the C12 are warranted for 12 months and generally last 5 years or more in the absence of poi...

Страница 15: ...r local alarm of a high gas condition without the need for wiring back and forth to a remote alarm module In normal operation this version of the C12 17 will continuously display LEL on the integral l...

Страница 16: ...C12 17 Combustible Gas Transmitter 17 O M Manual Rev D Figure 9 Transmitter with Display Customer Connections ATI 0570...

Страница 17: ...is done using a magnet through the window of the display A magnetic screwdriver is supplied with the transmitter for this purpose If the relay activates and the gas concentration returns to normal sim...

Страница 18: ...ploded View ATI 0146 Part Number Description 00 1256 C12 17 Combustible Transmitter Module 80 0017 Explosion proof Enclosure 00 1198 D10 17 Combustible Sensor Assembly 92 0043 10 32 x 1 PHMS S S Phill...

Страница 19: ...oded View ATI 0571 Part Number Description 00 1258 C12 17 Combustible Transmitter Module with Display 80 0074 Explosion proof Enclosure for Display Module 00 1198 D10 17 Combustible Sensor Assembly 92...

Страница 20: ...improper storage or extended exposure to excessive gas concentrations Should inspection indicate that sensors have failed due to any of the above the warranty shall not apply The Manufacturer assumes...

Страница 21: ...DUCTS NH3 Ammonia CO Carbon Monoxide H2 Hydrogen NO Nitric Oxide O2 Oxygen CO Cl2 Phosgene Br2 Bromine Cl2 Chlorine ClO2 Chlorine Dioxide F2 Fluorine I2 Iodine HX Acid Gases C2H4O Ethylene Oxide C2H6O...

Отзывы: