Monthly/ Six Monthly / Yearly Routine Maintenance
Visually inspect the Auto Control box for damage. Any damage will admit water causing the premature
failure of the electronics and should be fixed as soon as possible.
Parlour Wash Down
The Auto Wash Pro control enclosure is IP65 rated. However, no indirect or direct pressure washing
should be used to wash the Auto Wash Pro Control, as this will cause the seals to fail and water to ingress
and damage the electronic components. Please note that water damage is not covered under warranty.
Troubleshooting
The Auto Wash Pro reports errors to the user, when a error occurs the control will ‘Beep’, pressing the
Info key will show the user what the error is.
The list is a list of the errors which may occur on the Auto Wash Pro, with possible resolutions.
Error
Fault Information
XXXXXXXXXX FUSE
WHITE
TEXT FOR SPACING
SYSTEM PSU FAIL
WHITE
TEXT FOR SPACING
PUMP PSU FAIL
WHITE
TEXT FOR SPACING
VAC LEVEL LOW
WHITE
TEXT FOR SPACING
VAC LEVEL HIGH
WHITE
TEXT FOR SPACING
CHECK CHEMICAL
WHITE
TEXT FOR SPACING
IO BOARD ERROR
WHITE
TEXT FOR SPACING
WASH T INPUT ERROR
WHITE TEXT FOR SPACING
MILK T INPUT ERROR
WHITE TEXT FOR SPACING
IO BRD COMM ERR
WHITE
TEXT FOR SPACING
WASH T LEVEL SXX
WHITE
TEXT FOR SPACING
RTRN W TEMP SXX
WHITE
TEXT FOR SPACING
WASH T TEMP SXX
WHITE
TEXT FOR SPACING
Output electronic fuse has blown, check output for faults, where
XXXXXXXXXX is the output name.
The power supply for the control electronics on the Auto Wash Pro I/O
Board has failed, check the power supply.
The power supply for the pump outputs on the Auto Wash Pro I/O Board
has failed, check the power supply.
The vacuum level fell below the warning level during the milking or
washing program.
The vacuum level rose above the warning level during the milking or
washing program.
The conductivity failed to change when adding the checmical, check the
chemical drums.
The control board failed to correctly communicate with the I/O board,
check the wiring between the two.
The wash trough input was not made when the control was put into a
wash program, the program cannot start.
The milk tank input was not made when the control was put into the
milking program, the program cannot start.
The I/O Board communications failed, check the wiring between the
control and the I/O board.
The wash trough failed to fill to the required level during the step XX of
the previous program.
The return water failed to reach the required temperature during step
XX of the previous program.
The wash trough failed to reach the required temperature during step XX
of the previous program.