Innovation In and Out of Parlour
©
A
TL
A
g
ricu
ltu
ra
l
Te
ch
n
olog
y
L
imite
d:
Ju
ly
2
0
1
8
47
| Auto Wash Pro Manual | v1.2
s01 CON ) 150.0mS
Step will complete
when conductivity
level is greater than
150mS
s01 INPUT 1 ON
Step will complete
when input matches
desired state
Setting can be ON or OFF
Info
Clear
Hot Water 1
Hot Water 2
Cold Water
Vac Build Up
Drain
Diverter
Separation
End Of Wash
Vac Pump 1
Vac Pump 2
Vac Pump 3
Vac Pump Stop
Milk Pump 1
Milk Pump 2
Air Blast
Pulsation
Auto Drain
Output 1
Output 2
Output 3
Milking LED
Washing LED
Solid State Relay 1
Solid State Relay 2
Peristaltic Pump 1
Peristaltic Pump 2
Peristaltic Pump 3
Peristaltic Pump 4
maX C 00--10--00.0
Stop
Reset
Stop
Reset
C = continue to next step
S = stop program and warn user
HH - hours
SS - seconds
MM - minutes
T - tenths of seconds
Can be less than (<) or greater than (>) X temperature
Input Number - 1 or 2
Editing Programs Continued
- Available Step End Conditions
Pressing the Info key
allows the user to edit which outputs are ON during each step - the same
functionality as the
I/O PCB test list. The outputs available are:
Maximum Step Run Time
Pressing the Stop key
shows the maximum step time and controls what happens when this
time is completed.
The maximum step time is used to determine what happens if a condition is not met after the allowed
time, the program can either continue, or stop on error.