ATI Audio DA2008 Скачать руководство пользователя страница 5

 

Day Sequerra 

 154 Cooper Rd. #902 

 W. Berlin, NJ 08091 

 Voice 856-719-9900 

 [email protected] 

 www.atiaudio.com 

Caution:

 Balanced differential outputs have active drivers for both HI and LO 

output terminals. DO NOT GROUND either HI or LO terminals. Two separate 
600 ohm unbalanced loads can be driven from each output without interaction by 
connecting one between HI and GND and the other between LO and GND. The 
two loads thus driven will be out of phase with each other.  
 
Maintenance Notes 
IC power supply voltages are + and –16 VDC nominal. If zeners are replaced, 
remove ICs and check output voltage before plugging ICs back into the circuit. 
Remove power when inserting or removing or ICs. 
 
IC output DC voltages (no signal conditions) should measure OVDC + .5 VDC. 
Significant deviation indicates IC or circuit problem. Measurable DC difference 
b amplifier inputs (other than due to meter loading) indicates IC failure. 
 

 

 

MODIFICATIONS 
 

230 VAC Operations 
 
Your DA is wired for 115 VAC 50/60 HZ operations unless otherwise requested 
at the time of ordering. It can be modified for 230 VAC use by removing the 
power transformer primary jumpers J1 and J3 and inserting a jumper in the J2 
holes. 
 
Gain 
To increase gain by 10db, change R25 (R26) to 680 ohms, and increase C23 
(C24) to 68 microfarads. 
 