ATI Audio DA2008 Скачать руководство пользователя страница 4

 

Day Sequerra 

 154 Cooper Rd. #902 

 W. Berlin, NJ 08091 

 Voice 856-719-9900 

 [email protected] 

 www.atiaudio.com 

POWER SUPPLY 

 
Your DA power supply incorporates a couple of unique regulating devices called 
zener diodes. In contrast to most fancy IC regulators, these devices will live 
through most line transients and simultaneously protect your expensive circuitry. 
As further insurance, a varistor suppressor is placed across the power 
transformer secondary. 

 
 

INSTALLATION 

 

MOUNTING 

 
Your DA may be desk mounted on its non-slip suction cup, or rack mount system 
21075-501 mounts two units in one rack. 

 
 

WIRING 

 
There are three wire grounded plugs.  The third wire ground can cause a ground 
loop with your station ground. If you are sure your station ground will provide 
adequate protection to personnel in case of an AC line short to chassis, a 3 to 2 
AC adapter can be used to isolate the power line ground. We recommend that 
the adapter be removed and the power line ground reconnected prior to any 
service work requiring removal of the station ground from the DA chassis. 
 
The four inch silver bearing copper strap, which you are, of course, using for your 
station ground is not going to fit around the #6 chassis ground screw on the 
DA2008 rear panel. Run the strap to within a few inches of the chassis and jump 
to the chassis ground with shield braid. 
 
Audio inputs and outputs should be connected using the rear panel labels as a 
guide. Hi outputs are all in phase with each other and in phase with the Hi inputs. 
Fanning strips are provided so that our ears won't be burning in the middle of the 
night while you are trying to wrap wires around those tiny barrier strip screws. 
The fanning strips are Kulka part number 649A22 and extras are available from 
our parts and accessories department. For convenience, the fanning strips may 
be easily cut into shorter input or output sections. 
 
To allow maximum flexibility in grounding in high RF environments, the circuit 
grounds are isolated from case ground. For normal operations, add a ground 
jumper from the barrier strip ground terminal closet to the inputs to the chassis 
ground screw. 
 
 