background image

12

13

|     ATHLONOPTICS.COM

ATHLONOPTICS.COM     |

A) ILLUMINATION SETTINGS

The illumination switch is set on the left side of the 

scope chassis. Athlon offers variable 1-10 brightness 

settings  and  two  colors  settings  (red  and  green)  for 

the reticle.  Press UP button to turn the unit ON. Press 

and hold the UP button for 3 seconds to turn it OFF. 

Use  the  UP  button  to  make  the  reticle  brighter  and 

the DOWN button to make it dimmer. The unit auto

-

matically turns OFF if no adjustments are made in 6 

hours. Press UP and DOWN button at the same time to 

switch between reticle colors. The unit automatically 

sets  the  illumination  at  the  last  setting  after  a  new 

battery is installed.

Illumination Switch

Battery Chamber Cap

The  illumination  is  powered  by  a  AAA  battery.  Re

-

move  the  battery  chamber  cap  by  turning  it  count

-

er-clockwise and then set the battery with the posi

-

tive (+) side facing in. Reinstall the cap by turning it 

clockwise, DO NOT OVER TIGHTEN.

3. MAINTAINING YOUR PRISM SCOPE

Disassembling  or  cleaning  the  scope  internal

-

ly  will  void  the  warranty.  If  the  scope  requires 

repairs,  please  refer  to  the  warranty  section  for 

complete instructions.

  

The external optical surfaces should occasionally 

be wiped clean. Use the lens cloth provided or an 

optical quality lens paper to wipe out dust or dirt 

on the external lens surface. If large sand parti

-

cles or heavy dirt contamination is observed, re

-

move using soft brush or by blowing them away. 

Apply lens cleaning liquid before wiping off. Al

-

ways  keep  the  protective  lens  covers  in  place 

when the scope is not in use to avoid dust collect

-

ing on the surface of the lenses. Store the unit in 

a low-humidity environment.

a)

b)

Содержание TSP1

Страница 1: ...PRISM SCOPE USER MANUAL CARE INSTRUCTIONS TSP1 ...

Страница 2: ...nsmith Your Athlon Prism Scope comes with a mount that works with most of standard picatinny rails Please note that the center height of the Prism Scope is 1 39 inches from the center of the scope to the surface of the rail TABLE OF CONTENT 1 Mounting the Scope a Focusing the Scope b Adjustment for Maximum Eye Relief c Bore Sighting d Zeroing the Scope 2 Reticle 3 Maintaining the Scope 4 Troublesh...

Страница 3: ...unt to avoid injury from recoil ii With the rifle in normal shooting position look through the scope and slowly move the scope and mount back towards you When you finally see the full field of view with sharp and clear edges stop iii Tighten the mount on the base or rail on top of your rifle C BORE SIGHTING Bore sighting is a preliminary procedure to achieve proper alignment of the scope with the ...

Страница 4: ...enter of reticle up down left or right Fire an other three rounds then observe and adjust Re peat this step as necessary until the three round bullet holes are perfectly aligned with the center of the target ii Setting Windage and Elevation Athlon Prism Scopes have capped windage and elevation turrets Simply remove the cap and use the knob on the top of the cap as a screwdriver to adjust the winda...

Страница 5: ...ification with TSP1 reticle Please refer to following drawing for reticle subtension details TSP1 RETICLE Elevation Turret Knob Windage Turret Knob A1 B1 B2 D1 A1 A2 B4 B3 C1 C2 C3 C4 D3 D2 SUBTENSIONS IN MOA A1 A2 B1 B2 B3 B4 C1 2 3 7 6 10 2 15 10 5 9 C2 C3 C4 D1 D2 D3 5 6 13 2 22 3 2 66 ...

Страница 6: ... Rem 5 56 mm NATO rounds It is suitable for many bullet weights in these calibers The bullet holdovers can be found in the following illustration RANGING The TSP1 reticle can be used for ranging a target of an average human height 69 inches 200 yds 100 yds 200 yds 300 yds 300 yds 500 yds ...

Страница 7: ...ered by a AAA battery Re move the battery chamber cap by turning it count er clockwise and then set the battery with the posi tive side facing in Reinstall the cap by turning it clockwise DO NOT OVER TIGHTEN 3 MAINTAINING YOUR PRISM SCOPE Disassembling or cleaning the scope internal ly will void the warranty If the scope requires repairs please refer to the warranty section for complete instructio...

Страница 8: ... is not damaged and no excessive grease inside the barrel For any technical related questions please con tact Athlon Optics at contact athlonoptics com or call toll free 1 855 913 5678 a b c d e f g THE ATHLON GOLD MEDEL LIFETIME WARRANTY Your Athlon product is not only warranted to be free of defects in materials and workmanship for the life time of the product Athlon will also repair or replace ...

Страница 9: ...Toll free 1 855 913 5678 contact athlonoptics com 801 N MEADOWBROOK DR OLATHE KS 66062 ATHLONOPTICS COM SHARP TIGHT AND PRICED JUST RIGHT ...

Отзывы: