www.atestgaz.pl
Storing, in the memory of the gas detector such parameters as: substance CAS number, location
name, serial number, the intervals between mandatory calibrations, etc.
1.2
Marking of explosion protection
Figure 2: Information on the rating plate of the device
No.
Description
1
Number of the notified body responsible for supervision of the device
2
Numbers of Ex certificates issued for the device
3
Ex code for the device
4
Information about temperature class
Table 2: Meaning of information provided on the rating plate
1.3
Cable glands
The cable gland is a replaceable element. When selecting cable gland make sure that it implement all of the
following requirements:
degree of explosion protection – no worse than the detector,
operating temperature range – at least as wide as the detector,
have the right thread – see the device nameplate,
have a nylon washer to protect the enclosure (in the case of aluminium enclosure).
Details see chapter 7.
1.3.1
Replacement of cable glands
To replace/screw the cable gland:
remove the gland from device (if it is screwed in),
apply small amount of technical vaseline on the thread of the gland,
screw in a new gland.
p
. 7|28
User Manual: POD-061-ENG R03
3
4
1
2