www.atestgaz.pl
Register map of SmArtGas 3 and ProGas Gas
Detector
All the data are available in the 'holding registers' (function code 3).
Register
Name
Description
Type
40001
State_A
Detector status – the definition of bits below
flags
40002
-
Inessential data, can take any value
-
40003
N
Gas concentration
A value of 0 corresponds to the 0 concentration, the value of
1000 corresponds to a concentration of the range of the
detector
16 bit integer
40004
-
Inessential data, can take any value
-
40005
Sample_Cnt
Sample counter. The value is increased by 1 after each
measurement. It takes values from 0 to 255
Total number 16 bit
State_A - detector status. The meaning of the bits is described in the table below.
Bit
Name
Description
0
Collective_W1
Gas concentration is above first warning threshold
1
Collective_W2
Crossing the second warning threshold
2
Collective_AL
Crossing the alarm threshold
3
Collective_CrFail
Collective information about a critical failure
4
Collective_NonCrFail
Collective information about a non-critical failure
5
Gas_Hi_Range
Operation on a coarse measuring channel (for type 2 and 3).
6
Gas_HiHi_Range
Gas overload
7
Sensor_Lock
Lock of the sensor (the last measurement was locked)
8
Calibration
Calibration mode
9
Test
Test mode
10
Warm_Up
Sensor warm-up
11..15 -
Inessential data, can take any value
Atest-Gaz
A. M. Pachole sp. j.
ul. Spokojna 3, 44-109 Gliwice, Poland
VAT No.: PL 9691433231
tel.: +48 32 238 87 94
fax: +48 32 234 92 71
e-mail: [email protected]
p. 1/1
Appendix: PU-Z-056-ENG R01
•