Technical specification

Power supply

• V

CC

• I

CC

10.5 – 30 V 
up to 35 mA

Environment

In operation

Storage 

• Ambient temperatures
• Humidity

0 – 40

O

C

10 – 90% long term

0 – 99% short term

0 – 40

O

C

30 – 90% long term

IP

IP20

Analogue outputs parameters
• R

OBC_MAX

• Discrete current signal

240 Ω

4 – 20 mA

Inputs parameters
• Type of inputs

• Max resistance of bus and relay contact
• Activation signal

Two-state,   to   work   with   galvanically   separated   contact   or

semiconductor relays
< 10 Ω
Only information about the state with the higher priority is transferred

Protection class

III

Dimension

See Figure 2

Acceptable cables

1 – 1.5 mm

2

Enclosure

Self-extinguishing PPO

Weight

< 0.1 kg

Mandatory periodic inspection

Test as often as the parent device

Mounting

On DIN-35 / TS35

Table 5: Technical specification

6

Product marking

Product code

Device

PW-048-A

MOD CNV PK420 Control Unit Module

Table 6: Product marking

7

Appendices

[1] 

DEZG021-ENG  EU Declaration of Conformity – MOD CNV PK420

[2] 

PU-Z-077-ENG Connection diagram for MOD CNV PK420 with Alpa MOD LED8 and EcoAlpa /

Alpa P17

[3] 

PU-Z-109-ENG Connection diagram for MOD CNV PK420 with Alpa MOD LED1 and EcoAlpa /

Alpa P17

s. 9|9

User Manual: POD-016-ENG R01

Содержание MOD CNV PK420

Страница 1: ...POD 016 ENG R01 User Manual Control Unit Module MOD CNV PK420 Product code PW 048 A...

Страница 2: ...ring Detection and Reduction of gas hazards We invite you to familiarize yourself with our offer on www atestgaz pl Atest Gaz A M Pachole sp j ul Spokojna 3 44 109 Gliwice Poland tel 48 32 238 87 94 f...

Страница 3: ...guarded may need consideration of other requirements during the entire lifetime of the product How to use this manual The following symbols of optical indicators status are used throughout the documen...

Страница 4: ...ication of output signals produced by the Signal Converter Module MOD CNV PK420 5 Table 3 Specification of the terminal block 6 Table 4 Maximum runs of cable sections 7 Table 5 Technical specification...

Страница 5: ...her processing by a Central Control Unit e g EcoAlpa Alpa P17 MOD LED8 etc For normal operation of the unit the PK FAILURE output of a control device wired to the MOD CNV PK420 module must be inverted...

Страница 6: ...rs in Section 5 AL Tripping line for the ALARM signal OS Tripping line for the WARNING signal P Tripping line for the OPERATION signal Plus pole for tripping signals 2 Output Output port Plus pole for...

Страница 7: ...imilar cables with sufficient cross section of cores see Table 5 Maximum runs for the cable sections to wire the PK420 converter to a Control Unit with consideration of cable core cross section a list...

Страница 8: ...f with other household waste Instead it is the user s responsibility to ensure disposal of waste equipment by handing it over to a designated collection point for the recycling of waste electrical and...

Страница 9: ...ut the state with the higher priority is transferred Protection class III Dimension See Figure 2 Acceptable cables 1 1 5 mm2 Enclosure Self extinguishing PPO Weight 0 1 kg Mandatory periodic inspectio...

Страница 10: ...he use of certain hazardous substances in electrical and electronic equipment EN 50581 2012 This declaration of conformity is issued under the sole responsibility of the manufacturer Purpose and scope...

Страница 11: ...Gliwice Poland VAT No PL 9691433231 tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl Appendix PU Z 077 ENG R01 s 1 1 Alpa MOD LED8 MOD CNV PK420 Channel 1 EcoAlpa Alpa P17 S Detector...

Страница 12: ...chole sp j ul Spokojna 3 44 109 Gliwice Poland VAT No PL 9691433231 tel 48 32 238 87 94 fax 48 32 234 92 71 e mail contact atestgaz pl Appendix PU Z 109 ENG R01 s 1 1 Input Channel 1 EcoAlpa Alpa P17...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Отзывы: