The detector should be mounted with the use of Ø6 rawl bolts or M5 screws using the mounting
holes accessible after the housing is open, so that the gas inlet is directed downwards. The
housing dimensions, mounting hole spacing and the arrangement of the elements are shown in
the figure 1. To make the holes it is recommended to use drilling template enclosed in the
packaging of the unit.
If the connection was made with the use of multi-wire cables (commonly known as a "cord"), the ends of
these connectors should be ended with clamp sleeves.
If there is a need to connect two conductors in one terminal of the device, the only allowable option is to
connect them in a common clamping sleeve (details are provided in table 8).
It is unacceptable to combine in one connector two wires which are not pinched in one cable
lug.
Do not place the cable reserve in the device. Bare wires or wires surplus may create a danger
of electric shock or equipment damage.
Do not leave disconnected cables inside the device.
Incorrect cable routing can lead to reducing the device's immunity from electromagnetic
interference.
Figure 7: Example connection of cables to the device