ATESS EVD-40D Скачать руководство пользователя страница 4

 I. Product description

1. HMI;                                                              6. Air outlet;   
2. Charging connector holder;                      7. Mounting bracket;
3. RFID reader;                                               8. Emergency Stop button;
4. LED indicators;                                           9. Charging connector holder;
5. WIFI/4G antenna                                        

Explanation of LED indicators behaviors:
Blue - Standby(The charging equipment can only be used when the blue light lit);
Red Steady on/Flashing - Fault;
Green Steady on - Charging in process;
Green Flashing - Establishing communication;
Yellow Flashing - System initializing.

Internal view and terminal definition

1. AC input RCBO;
2. SPD

3. AC  input  terminal  block.  Terminal  definition  is  (

L1;

L2;

L3;

N)  from 

right to left;
4.PE terminal;

Fig: AC Surge protection device

Note:  The  charging  equipment  will  detect  the  current  status  of  the  lightning 
arrester  module  in  real  time.  When  the  lightning  protection  module  is  damaged, 
the  display  will  have  an  alarm  indicating  that  the  lightning  protection  device  is 
faulty. When repairing and replacing the lightning protection module, the left side 
cover  must  be  removed  first.  Then  the  maintenance  person  can  operate  the 
breaker in the surge protection circuit and replace the lightning protection module! 
(The  red  circle  in  the  figure  is  the  lightning  protection  status  indicator.  When  the 
indication  window  indicates  green,  the  lightning  protection  module  is  normal; 
when  the  indication  window  indicates  red,  the  lightning  protection  module  has 
been  broken  and  damaged,  and  the  lightning  protection  module  needs  to  be 
replaced.)

6

5

7

9

8

1

3
4

2

1

3

2

4

Содержание EVD-40D

Страница 1: ...ser manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E info...

Страница 2: ...connector works independently Up to 2 EV could be charged at the same time All the above features make it most suitable for outdoor charging We sincerely hope that this product can meet your needs and...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...n device Note The charging equipment will detect the current status of the lightning arrester module in real time When the lightning protection module is damaged the display will have an alarm indicat...

Страница 5: ...d 3 holes for cable hooker mounting on the wall Take out the expansion bolts in thepacking accessory bag hammer the expansion bolts into the holes Remove the nuts and washers for later use 2 Loosen th...

Страница 6: ...internal wiring and breaker position The wiring is then finished Notice 1 Only professional personnel can do the wiring connect the AC input wires in correct phase order according to the markings on...

Страница 7: ...n may consist of multiple charging equipment 5 Number of power modules Number of power modules inside the mode 4 charging equipment 6 Modules power Rated power setting of power module 7 Plug and Charg...

Страница 8: ...Authentication Key OCPP login authentication setting 4 3 Protection parameters The protection related parameters such as voltage current temperature power etc No Parameters Function description 1 2 3...

Страница 9: ...e Charging will start automatically after EV plugged in If you want to stop the charging just press the stop icon on the screen Plug Charge mode operation process flow The charging equipment is equipp...

Страница 10: ...he 4 digit password A wrong password will cause no response and action System parameters page Network parameters page used to set network related parameters of back office server and the charging equi...

Страница 11: ...fault Plug line disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 40D Dimension mm 775 556 270 L W H Weight...

Страница 12: ...t Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 25 50 derate since 50 Ip54 5 95 2000m derate for higher than 2000m Forced air c...

Страница 13: ...7 3 Contact Company Name Shenzhen Atess Power Technology Co Ltd Address 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China Web...

Отзывы: