ATESS EVD-40D Скачать руководство пользователя страница 12

IP degreel

Working environment

Relative humidity

Altitude

Cooling method

Remote monitoring

Payment

Standby power

Standards

Mounting

Metering accuracy

Certificate

Protection features

Low and high trip limit of AC 
input voltage

Over voltage trip limit of DC 
output

Over temperature protection

Short circuit protection

Emergency stop protection

Lightning protection

Leakage protection

-25

~+50

derate since 50

Ip54

5

%-

95

%

≤2000m, derate for higher than 2000m

Forced air cooling

Ethernet/WIFI/4G/485/232

RFID/APP

25W

IEC-62196-1;IEC-62196-3;

Wall or Pole

CE

0.5

Adjustable within 260~457V AC

Adjustable within 260V~778V DC

Yes

Derate since 50

;

 

Stop at 75

Yes

Type A

Type II

VII. Appendix

7.1 Electric diagram

F

ig

7

-1

, M

a

in c
ir

c

u

it d
ia

g

ra

m

Содержание EVD-40D

Страница 1: ...ser manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E info...

Страница 2: ...connector works independently Up to 2 EV could be charged at the same time All the above features make it most suitable for outdoor charging We sincerely hope that this product can meet your needs and...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...n device Note The charging equipment will detect the current status of the lightning arrester module in real time When the lightning protection module is damaged the display will have an alarm indicat...

Страница 5: ...d 3 holes for cable hooker mounting on the wall Take out the expansion bolts in thepacking accessory bag hammer the expansion bolts into the holes Remove the nuts and washers for later use 2 Loosen th...

Страница 6: ...internal wiring and breaker position The wiring is then finished Notice 1 Only professional personnel can do the wiring connect the AC input wires in correct phase order according to the markings on...

Страница 7: ...n may consist of multiple charging equipment 5 Number of power modules Number of power modules inside the mode 4 charging equipment 6 Modules power Rated power setting of power module 7 Plug and Charg...

Страница 8: ...Authentication Key OCPP login authentication setting 4 3 Protection parameters The protection related parameters such as voltage current temperature power etc No Parameters Function description 1 2 3...

Страница 9: ...e Charging will start automatically after EV plugged in If you want to stop the charging just press the stop icon on the screen Plug Charge mode operation process flow The charging equipment is equipp...

Страница 10: ...he 4 digit password A wrong password will cause no response and action System parameters page Network parameters page used to set network related parameters of back office server and the charging equi...

Страница 11: ...fault Plug line disconnection fault AC Contactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVD 40D Dimension mm 775 556 270 L W H Weight...

Страница 12: ...t Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 25 50 derate since 50 Ip54 5 95 2000m derate for higher than 2000m Forced air c...

Страница 13: ...7 3 Contact Company Name Shenzhen Atess Power Technology Co Ltd Address 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China Web...

Отзывы: