3.2.4 Fix the mounting bracket onto the pole.

3.2.5  Position  the  charge  point  onto  the  bracket  and  secure  it  on  the  bracket  with  the  2 
screws.

3.2.6 Crimp the below shown insulated ferrule or ring terminals on the end of the AC input 
wires. Connect the wires into the terminal block of the charge point as below. Check the 
wiring and then close the RCD in the side window. Close the side window with the cover, 
then the wring is done.

After the installation and wiring is done, connect the Charger to a computer and configure 
parameters via the web browser of the computer, then the Charger can be ready for use.

IV. 

 Parameter setting

4.1 Set computer’s IP

The  Charger’s  default  IP  address  is  192.168.1.5.  To  access  the  parameter  setting 
interface,  you’ll  need  to  first  set  the  computer’s  IP  to  192.168.1.x(x  can  be  any  value 
between 1 and 255 except for 5, e.g. 192.168.1.10).

To set a static IP on your Windows computer:

1. Click Start Menu > Control Panel > Network and Sharing Center. (For Windows 8 and 
higher, search for and open Control Panel and select Network and Internet).

2. Click Change adapter settings.

 

7

8

Содержание EVA-03S

Страница 1: ...ent Quick user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen C...

Страница 2: ...iption II Pack list III Installation and wiring IV Parameter setting V Operation instruction VI Firmware update VII Troubleshooting VIII Use excess solar power to charge your car IX Intelligent power...

Страница 3: ...window nameplat 8 Waterproof cable gland for communication wires 9 Waterproof cable gland for AC input cables Wiring definition in the side window 5 6 7 9 1 2 3 4 8 1 Terminal block for CT meter wirin...

Страница 4: ...fixing III Installation and wiring 4 3 3 1 1 Open the packaging you ll see a charge point a mounting bracket a user manual and a bag of mounting accessories There is also an RFID card if the charge po...

Страница 5: ...ow Close the side window with the cover then the wring is done 3 2 Mount on a pole 3 2 1 Open the packaging of the pole take out the pole and mounting accessories 3 2 2 The pole must be installed on a...

Страница 6: ...tion and wiring is done connect the Charger to a computer and configure parameters via the web browser of the computer then the Charger can be ready for use IV Parameter setting 4 1 Set computer s IP...

Страница 7: ...browser on a computer It is suggested to use IE or Firefox other browser might have compatibility problem 4 2 Configure parameters 3 Right click on Local Area Connection and click on Properties 4 Sel...

Страница 8: ...meters Fig 1 2 Charger ID this is the unique identification of the Charger If the charger is to be connected to ATESS back office server this ID must be set as the serial number on the nameplate of th...

Страница 9: ...cation Key and Heartbeat Interval is used for testing and no need to reset Fig 7 Fig 8 9 PIN of the charger used to verify the PIN of user card To use a RFID card with the charger their PIN must be co...

Страница 10: ...eters are used for power management setting Fig 19 23 Over temperature protection value not suggested to change 24 Charging allowed time Charging can only start within this time period This is used fo...

Страница 11: ...firmware Fig 28 V Operation instruction 5 1 Charging mode and Operation APP RFID mode Initiate or cease charging by scanning QR code using APP or by swiping RFID card You can also use APP for reservat...

Страница 12: ...the charger Plug Charge mode operation process flow VI Firmware update There are 2 ways to update firmware for EV charger 1 Update by SD card 2 Update on parameter setting page 6 1 Update by SD card...

Страница 13: ...ger to computer via a network cable the computer s IP must be within the 192 168 1 x segment x is any value between 1 and 255 except 5 Open the web browser type in the charger s default IP of http 192...

Страница 14: ...he firmware file Click Upload then update will start automatically VII Troubleshooting 7 1 Troubleshoot by LED behavior or LCD display If fault occurs users can check the fault information on the LCD...

Страница 15: ...Signal strength on mobile b Please check and input the correct WiFi SSID and password to retry If you check the WiFi setting on the APP please turn off and back on the charger and connect your mobile...

Страница 16: ...net 2 Click Change adapter settings 27 28 d 1 Some routers have 2 WiFi one is 2 4GHz the other is 5GHz Most homes just use the 5GHz WiFi as their default WiFi But the charger can only connect to the 2...

Страница 17: ...if you have input the complete content which is http 192 168 1 5 8080 in the address field do not leave out the http or the 8080 e Sometimes you may need to restart the charger to access its parameter...

Страница 18: ...monitor the real time power import and export a CT or meter is needed for this function to work properly If CT is used the wiring will be as below ECO Mode In this mode the charging point only uses th...

Страница 19: ...s of solar mode charge FAST ECO and ECO 3 Select CT or meter as sampling device of this solar charge function Scroll down to find the option External Power Sampling Wiring 0 Inner CT 1 PowerMeter If C...

Страница 20: ...to find the following parameter Power Distribution Enable 0 Disable 1 Enable and set it to 1 to activate the power modulation function N L L N White RED CTK 16 2 0 Semonsen123 L N L N L L N L_IN N_IN...

Страница 21: ...to the address shown on the meter X Specification Model EVA 03 07S Dimension mm 380 240 145 L W H Weight kg 7 Display LCD Casing Material Stainless steel Engineering plastics Tempered glass Input Vol...

Страница 22: ...ntact Company Name Shenzhen Atess Power Technology Co Ltd Address 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China Website w...