background image

Setting

Function

SET PASSWORD

This function is used to set passwords for the Administrator and User:

1. One Administrator and four User passwords can be set.
2. Move the highlight bar to User or Administrator, then press [Enter].

A screen that allows you to key in your password appears. The
password may be up to 8 characters long, and can consist of any 
combination of letters and numbers (A - Z, 0 - 9). 

3. Key in the new password, then press [Enter]. You are asked to key

the password in again, in order to confirm that it is correct.

4. Key in the new password again, then press [Enter].

If the two entries match, the new password is accepted. If the 
entries do not match, you must start again from the beginning.

5. To modify or delete a previous password, use the backspace key 

to erase individual letters or numbers.

6. If the Administrator wants to change a User’s password, he must 

enter his Administrator’s password first. 

SET ACCESSIBLE
PORTS

This function allows Administrators and Users to select which Ports
can be accessed from a particular Console. Move the highlight bar to
the target computer, then press [Enter] or the [Spacebar] to toggle
access On and Off. If access is On, a plus mark ( + ) appears to
indicate so. If access is Off, the area is blank. Make your choice,
then press [Esc] to confirm.

SET MULTIUSER MODE

This function determines whether or not the same ID can be used to
log into the CS-428 from different Consoles at the same time.

1. If Disabled, the same ID cannot be used; if Enabled (the default), 

the same ID can be used to log in from more than one Console.

2. If Enabled, the F4F6, and F7 settings set for any one Console, 

will be the same for all other Consoles that log in with the same ID. 

3. Changes made to the F4F6, and F7 settings by any logged in 

Console will automatically affect all Consoles with the same ID.

SET ACCESS TIMEOUT

This function is used to set the timeout value to control the release of
access rights to a computer. If the original Console doesn’t access the
computer before the timeout value is reached, the computer becomes
available to the other Consoles. To set the timeout value, key in a
number from 2 - 255 seconds, then press [Enter] (if the number is 0
[zero], this function is disabled. Default is 010 (ten) seconds.

CLEAR THE NAME LIST

This function is used to undo all Administrator changes and return
the setup to the original factory default settings.
Note: While this function is in progress, make sure that no other 

operations are performed on any of the other Consoles.

RESTORE DEFAULT
VALUES

This function is used to undo all Administrator changes and return
the setup to the original factory default settings - except for the
Names that were assigned to Ports, which are saved.

2001-03-01

CS-428 User Manual

15

Содержание CS428

Страница 1: ...User Manual CS 428 4 Console 8 Computer KVM Switch 2001 03 01...

Страница 2: ...2001 03 01...

Страница 3: ...ping If you encounter a problem contact your dealer Please read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and or any of th...

Страница 4: ...on 7 Operation 9 Hot Plugging 9 Powering Off and Restarting 9 Port Selection 9 OSD Operation 10 OSD Overview 10 Port Numbering 11 OSD Navigation 11 OSD Main Menu Headings 12 OSD Functions 12 Factory D...

Страница 5: ...to the system by means of an on screen menu driven interface In addition a powerful Quick View Scan feature allows you to auto scan and monitor the activities of all operating computers on the instal...

Страница 6: ...For Cascaded Installations w OSD Automatically Adjusts to Resolution Changes w Hot Pluggable Add or Remove any Computer without Powering Off the Switch w Auto Scan Function Provides Easy Monitoring o...

Страница 7: ...ndard cables may damage the connected devices or degrade overall performance For optimum signal integrity and to simplify the layout we strongly recommend that you use the following high quality CS Cu...

Страница 8: ...that the Port is being used for Cascading to another Master View switch Selected Lights GREEN to indicate the currently selected port 2 K M Reset If the keyboard and mouse get stuck and need to be re...

Страница 9: ...icrophone and speakers belonging to Console 2 plug in here 5 Console 2 Mouse Keyboard and Monitor Connectors 6 Console 1 Microphone and Speaker Jacks The microphone and speakers belonging to Console 1...

Страница 10: ...ug the monitor keyboard and mouse cables for Consoles 1 and 2 into the port connectors located on the rear panel of the CS 428 unit Each port is labeled with an appropriate icon to indicate itself 2 P...

Страница 11: ...of Master View units needed to control them is provided in the Appendix Note 1 Only Master View CS 138A CS 9138 CS 128A or CS 124A units can be used with the CS 428 2 Master Views cannot be cascaded b...

Страница 12: ...irst Stage CS 428 8 Power on all Second Stage units 9 Plug in the power cords and power On all the computers You must follow the sequence in steps 5 9 when powering up 1 2 3 4 5 6 7 8 2001 03 01 8 CS...

Страница 13: ...its before starting it back up you must do the following 1 Shut down all the computers that are attached to the unit as well as all the stations Second Stage Master Views and all the computers that ar...

Страница 14: ...to provide your password If the password function has been set for the Console you are at you must provide the password in order to access the OSD Main screen If this is the first time that the OSD is...

Страница 15: ...ere are more items than appear on the screen the screen will scroll w To access a port Double Click it or move the Highlight Bar to it then press Enter Note 1 If you try to access a computer that has...

Страница 16: ...that the computer connected to this Port is powered On and is On Line NAME If a port has been given a name see F2 p 13 its name appears in this column OSD Functions OSD functions are used to configur...

Страница 17: ...meanings are given in the table below Choice Meaning ALL Lists the Port Numbers and Names if names have been specified see F2 of all the ports on the installation QVIEW Lists only the ports that have...

Страница 18: ...a Timeout countdown see Set Access Timeout and Set Logout Timeout in the table below a Z appears in front of the Port ID display to indicate that the Port is Pending i e the original Console that acc...

Страница 19: ...to confirm SET MULTIUSER MODE This function determines whether or not the same ID can be used to log into the CS 428 from different Consoles at the same time 1 If Disabled the same ID cannot be used i...

Страница 20: ...After you select an item a submenu with further choices appears To make a selection either Double Click it or move the Highlight Bar to it then press Enter An icon appears before the selected choice...

Страница 21: ...When Private Mode is Enabled none of the other Consoles cannot access the port and their monitors show a blank screen when they come to it If another console tries to access the port the message Priv...

Страница 22: ...rol of the computers and blanks the Console screen This is different from simply pressing Esc to deactivate the OSD since with this function you must log in all over again to regain access to the OSD...

Страница 23: ...29 9 CS 124A 29 32 Troubleshooting Symptom Possible Cause Action Keyboard and or Mouse not responding The connection from the selected port to the target computer has been broken or the computer is t...

Страница 24: ...Jacks 2 x Speaker Jacks Console 3 4 Connectors 2 x 25 pin D Type female Computer Port Connectors 8 x 25 pin D Type female On Screen Display OSD PC Names ID Numbers Port Status Scan Interval OSD Select...

Страница 25: ...rackets of the top unit with the four top brackets of the bottom unit then fit the top unit down onto the bottom unit w Rack Mounting To rack mount the unit do the following 1 First remove the stackin...

Страница 26: ...e required to take whatever measures may be required to correct the interference Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM THE DIRECT...