MODEL NO.:

Unfolded Size (With Handle):

Folded Size (With Handle):

Net Weight:

Cell Type:

Number of Cells:

Cell Efficiency:

Film Material:

Maximum Power (PM):

Open-Circuit Voltage (VOC):

Short-Circuit Current (ISC):

Maximum Power Voltage (VMP):

Maximum Power Current (IMP):

Maximum System Voltage:

Operating Temperature Range:

Temperature Coefficient of Pmax:

Temperature Coefficient of Voc:

Temperature Coefficient of Isc:

AP100MS

20.47"L (52cm) x 48.43"W (123cm) x 0.87"H (2.2cm)

20.47"L (52cm) x 24.21"W (61.5cm) x 1.77"H (4.5cm)

9.04lbs (4.1kg)

A Grade Monocrystalline

18 (3 x 6)

24%

PET

100W

22.6V

5.83A

18.36V

5.45A

600V

-

40°C ~ +85°C

-0.35%/ºC

-1.84mV/ºC

2.6mA/ºC

Junction Box

Wire Size:

16 AWG (3m Long)

50A Anderson to 30A Anderson Solar Adapter

Wire Size:

16AWG

Содержание AP100MS

Страница 1: ...USER MANUAL 100W Foldable Solar Panel AP100MS ...

Страница 2: ...cts that are optimally tailored to the needs of our amazing customers We engineer and supply solar products for homes 4x4s recreational vehicles and virtually any application you can think of And we also develop reliable high performing deep cycled batteries and lithium batteries for standby or daily power needs Accessories include battery chargers and inverters that are ideal for RV s commercial ...

Страница 3: ...ing may be damaged which can cause short circuit local overheating and decrease in efficiency Ensure nothing sharp or heavy could potentially break or damage the solar panel during transport or storage Do NOTconnect the solar panel directly to a battery An unconnected panel exposed to light may generate voltages greater than 20V on their leads Completely cover all panels with an opaque material du...

Страница 4: ... your solar panel with its four holes if you mount it onto the roof the back or the side of your vehicle Take out theAnderson plug from the accessory bag and connect it toATEM POWER portable power station Note Please make sure connection is tight When uninstalling you are required to repeat the steps from last to first 3 45 1 2 3 4 TIP Solar panels should be installed in a location where there is ...

Страница 5: ... IMP Maximum System Voltage Operating Temperature Range Temperature Coefficient of Pmax Temperature Coefficient of Voc Temperature Coefficient of Isc AP100MS 20 47 L 52cm x 48 43 W 123cm x 0 87 H 2 2cm 20 47 L 52cm x 24 21 W 61 5cm x 1 77 H 4 5cm 9 04lbs 4 1kg A Grade Monocrystalline 18 3 x 6 24 PET 100W 22 6V 5 83A 18 36V 5 45A 600V 40 C 85 C 0 35 ºC 1 84mV ºC 2 6mA ºC Junction Box Wire Size 16 A...

Страница 6: ...ct us The power station has a low voltage or current limit threshold Loose connection Large current of solar panels in parallel exceeds the current limit threshold of the power station Wrong tilt angle Shadow Accumulation of dust High operating temperature Only use the solar panel to charge a power station with input voltage 20V and input current 5A Reconnect Only use one solar panel to charge the...

Страница 7: ...osts of returning the product for a proven defect The limited warranty is the only one that applies to this unit and it sets forth all the responsibilities of ATEM POWER THE WARRANTY DOES NOT COVER Travel and or other expenses due to customer s location Damage caused by mould adverse weather extreme temperature accidents and daily wear and tear This unit is not intended for commercial use Non obse...