background image

 

Trouble Shooting 

Use the table below to solve minor UPS installation or operation 

problems.  If  any  abnormal  situations  occur  that  are  not  listed 

above, please call service people immediately. 

Symptom 

Possible Cause 

Remedy 

No LED display on 
the front panel. 

1. Missing battery. 

1. Charge battery up to 10 

hours. 

2. Battery defect. 

2. Replace with the same type 

of battery. 

3. When the Input cord 

isn’t electrified and 
Power switch is not 
pressed. 

3. Press the power switch 

again or electrify the Input 
cord 

Alarm buzzer 
beeps continuously 
when AC supply is 
normal. 

Overload of the UPS. 

Verify that the load matches 
the UPS capability specified in 
the specs. 

When power 
failure, back-up 
time is shorten. 

1. Overload of the UPS.  1. Remove some non critical 

load. 

2. Battery voltage is too 

low. 

2. Charge battery 10 hours or 

more. 

3. Battery defect due to 

high temperature 
operation environment, 
or improper operation 
to battery. 

3. Replace with the same type 

of battery. 

Communication 
lost between UPS 
and computer. 

1. Software is not 

installed well. 

1. Check the setting of the 

software. 

2. Cable is not properly 

connected. 

2. Check the RS-232 or USB 

cable is firmly connected 
to COM1/COM2 of the 
computer and confirm the 
setting again. 

Mains normal but 
LCD display 
Battery mode. 

1. Circuit breaker is 

broken. 

1. Reset the circuit breaker.. 

2. Power cord is loose. 

2. Reconnect the power cord 

properly. 

 

Содержание Blazer Vista 1000

Страница 1: ...USER MANUAL Blazer Vista 1000 1400 2000 Uninterruptible Power System ...

Страница 2: ...f position and disconnect the power cord form the AC power supply to properly disable the UPS Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in l...

Страница 3: ...arts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries This pluggable type A eq...

Страница 4: ...System Description Front Panel 1 LCD Back Light 2 Power ON OFF Switch Back Panel 1 Communication Port optional 2 Cooling Fan 3 AC Output 4 Modem Phone Line Surge Protection 5 Circuit Breaker 6 AC Input ...

Страница 5: ...all the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory...

Страница 6: ...ack of the UPS maximum of three devices 5 Modem Phone line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown ...

Страница 7: ...ow 7 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again When Switch ON The LED lighting 8 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3s ...

Страница 8: ...play as below And the mark will flicker every 1second Note If I P V 40V input voltage will display 000 4 When in off charging mode it will display as below Note the output voltage always is displayed as 000 in off charging mode 5 When in fault mode it will display as below FAULT character and the reason of fault only Note the fault code will be showed in fault mode ...

Страница 9: ... 100 7 Battery capacity definition Battery LEVEL Battery bar Indication Battery voltage 11V 11V Battery voltage 11 5V 11 5V Battery voltage 12 5V Battery voltage 12 5V 8 When over load the mark will flicker every 1second 9 When battery low the mark will flicker every 1second ...

Страница 10: ... on the same LAN no matter how far from the UPS Installation procedure 1 Go to the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DF2A to install the software When your computer r...

Страница 11: ...y that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 10 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Communication lost between UPS and com...

Страница 12: ...0 TRANSFER TIME Typical 4 6ms 4 8ms INDICATOR LCD Display Models The LCD will always turn on when UPS work Including in off charging mode and fault mode Fault Red LED lighting AUDIBLE ALARM Battery Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 second Battery Replace Sounding every 2 seconds Fault Continuously sounding PROTECTION Full Protection Discha...

Отзывы: