ALC-94 Series 



.



If the HOLD input is active the value on the display is frozen. Witout cutting the signal in the HOLD input 
the device will not count when the HOLD input is active. 



.



To activate the Hold type press and hold Prg and press Rst button. Find Hld.typ menu by UP DOWN 
buttons. Press Prg to see the menu. Press Prg again to flashing the options. Select the option and press 
Prg button to save the setting 



.



Press  and  hold  Prg  button  and  press  RST  button.find  Snstype  menu  by  Up  Dpwn  buttons.  Press  Prg 
button to display the menu.Press Prg again to make flashing the options. Select the intended option by 
Up Down buttons and save the option by pressing Prg button 



.





.



It is used for selecting the edge counting numbers of A, B signals of the encoder. Counting options are 
1,2, or 4. If the incremental encoder is connected to see the value in pulse type select 1 . When a linear 
encoder  connected  to  the  device  to  make  a  high  resolution  measurement  4  option  will  be  better 
(quadrature  mode).  To  change  the  edge  counting  option,  press  and  hold  Prg  button  and  press  Rst 
button.  Find the Cnt. Typ menu  by UP DOWN buttons. Press Prg to see the menu. Pres Prg again to 
make flashing the options.  
Change the options by UP DOWN buttons. Press Prg to save the selected option. 

Activating Hold Input ( Hld.inp ) 

 
 

Hold Type Selection ( Hldtyp ) 

 
 

Selecting Sensor Type (NPN/PNP)  ( Sns.typ. )  

 
 

Edge Counting Option ( Cnt.typ. )  

 
 

So it will be beneficial to save the important settings. The device asks you for a password to return to 
factory  settings.  It  is  454  To  restore  the  factory  settings  press  and  hold  Prg  button  and  press  Rst 
button.  Find  Fac.def  menu  by  UP  DOWN  butons.  Press  Prg  to  see  the  options.  There  is  YES  and  No 
options  in  the  menu.  Press  Prg  again  to  make  flashing  the  options.  If  you  press  to  yes  option  the 
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to 
other digits. Press Prg to save the return to the factory settings. 

Restoring Factory Settings ( Fac.def. )  

 
 



Factory menu used for restoring factory settings. All the settings will be changed by this menu. So it 
will  be  beneficial  to  save  the  important  settings.  The  device  asks  you  for  a  password  to  return  to 
factory  settings.  It  is  454.  To  restore  the  factory  settings  press  and  hold  Prg  button  and  press  Rst 
button.  Find  Fac.def  menu  by  UP  DOWN  butons.  Press  Prg  to  see  the  options.  There  is  YES  and  No 
options  in  the  menu.  Press  Prg  again  to  make  flashing  the  options.  If  you  press  to  yes  option  the 
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to 
other digits. Press Prg to save the return to the factory settings. 



Factory menu used for restoring factory settings. All the settings will be changed by this menu. So it 
will  be  beneficial  to  save  the  important  settings.  The  device  asks  you  for  a  password  to  return  to 
factory  settings.  It  is  454.  To  restore  the  factory  settings  press  and  hold  Prg  button  and  press  Rst 
button.  Find  Fac.def  menu  by  UP  DOWN  butons.  Press  Prg  to  see  the  options.  There  is  YES  and  No 
options  in  the  menu.  Press  Prg  again  to  make  flashing  the  options.  If  you  press  to  yes  option  the 
device asks you the password. The password sets by UP Down buttons and use LEFT button to pass to 
other digits. Press Prg to save the return to the factory settings. 

Recording When The Energy is OFF ( Record )  

 
 

Password Protection  ( Protec )  

 
 







Factory menu used for restoring factory 
settings. All the settings will be changed 
by this menu. 

 




The  used  sensor  can  be  selected  by  this  menu.  According  to  output 
type  of  the  sensor  NPN  veya  PNP  selection  allows  working  with 
different sensors

 

Содержание ALC-94 Series

Страница 1: ...ns 600 KHz reading speed 6 digit display Functional External Z input Functional HOLD input Quadrature mode up down counting 2 or 4 couple contact relay output Set 1 can be set related with Set 2 Optional factor value between 0 00001 and 999999 Optional decimal point between 1 and 5 digits 5 VDC or 12 VDC encoder power supply 11 various output control mode OFFSET value is adjustable Password Protec...

Страница 2: ...ED Signs by Out 1 output relay gets power 7 Out 2 output condition LED Signs by Out 2 output relay gets power 8 Out 3 output condition LED Signs by Out 3 output relay gets power Optional 9 Out 4 output condition LED Signs by Out 4 output relay gets power Optional ALC 94 Series FRONT PANEL DESCRIPTION FRONT PANEL USAGE Entering the value to numerical parameters Press RST and enter the programme the...

Страница 3: ...3 SOCKET CONNECTION ALC 94 Series DIMENSION and PANEL CUT OUT Panel cut out ...

Страница 4: ...esent SET value on the display When you press to PRG button again the last digit will flashing You can set the intended value by using UP DOWN buttons To pass to other digit press LEFT button The digit will pass left for each LEFT button pressing To change the point place POINT menu is used This subject will descripe in POINT MENU After presetting the intended value press PRG to save the value If ...

Страница 5: ... point the accuracy of the value can be selected Also the SET and HYSTERESYS manus poing place can be adjust by this command To adjust the point menu press and hold PRG button and press to RST button POINT menu can be found by UP DOWN buttons In POINT Menu when you press to PRG button you can see the setted point possition Press to PRG button and the value will be flashing By Up Down buttons you c...

Страница 6: ...enu Press Prg again to make flashing the options If you press to yes option the device asks you the password The password sets by UP Down buttons and use LEFT button to pass to other digits Press Prg to save the return to the factory settings Restoring Factory Settings Fac def Factory menu used for restoring factory settings All the settings will be changed by this menu So it will be beneficial to...

Страница 7: ...f the decrease down the Set values the Outputs don t turn off Only if the RESET comes the outputs turns off When the counting value reachs to Set 1 value Out 1 turn ON and also reachs Set 2 value Out 2 turn ON Out 1 and Out 2 keeps on state in following condition Counting Value Set 1 Counting Value Set 2 NOTE It must be following conditins for all Output modes OFFSET SET 1 SET 2 OUTPUTS ALC 94 Ser...

Страница 8: ...epend on the OUT 2 It should be enter the TOUT 2 is time and the TOUT 1 is HOLD Namely when the counting value reachs to Set 1 the OUT 1 turn on and if decrease under to Set 1 it s turn off When the counting value reachs to Set 2 the OUT 2 turn on and the counting value is held The counting value and outputs will be auto reseted in the end of the TOUT 2 time It is also Autoreset mode same as Outpu...

Страница 9: ...e reachs to Set 1 the OUT 1 turn on and if it decrease under the Set 1 OUT 1 turns off When the counting value reachs to Set 2 the OUT 2 turn on Even if the decrease down the Set values Out 2 doesn t turn off unless the counting value reach to OFFEST value If the RESET comes the outputs turns off The OUT 1 keeps on until the counting value reachs to SET 1 When the counting value reachs to SET 1 OU...

Страница 10: ... If the RESET comes the outputs turns off In this mode it should be selected the TOUT parameters as HOLD The OUT 1 keeps on until the counting value reachs to SET 2 When the counting value reachs to SET 2 OUT 1 turns off and OUT 2 turns on When the counting value increase and reaches reachs to Set 1 OUT 2 turns off and OUT 1 turns on If the RESET comes the counting value becomes the Offset ALC 94 ...

Страница 11: ...ensor com ALC77 RS 232 parameters are as follows There is setting on the devices Is one way communications device to the receiving terminal Data format RS232 EOL 16bit data EOL End of line character Baud rate 57600 bps Data bits 8 Stop bits 1 Parity none DATA PROTOCOL ALC 94 Series ERROR MESSAGES If the value is very high 999999 is written If the value is very low 999999 is written ...

Отзывы: